HIOKI Product Line - Power Analysis, Current Sensors, LCR/Impedance, Battery Testing
HIOKI is a manufacturer of innovative and high-quality devices for current sensing, power analysis and battery measurement technology. The product range includes battery testers and battery simulators, power analyzers and the matching current probes/sensors. In addition, HIOKI offers data loggers, devices for impedance analysis, R-, C- and LCR-meters as well as memory recorders.
Measurement technology since 1935: HIOKI produces everything from portable multimeters to battery testers, power analyzers to flying probe testers at its own plant in Ueda (Nagano Prefecture). The proximity between development and production guarantees the high product quality of the instruments. HIOKI develops and produces the instruments and current sensors itself, so that all components are perfectly matched to each other and have a consistently high quality level. Many devices of a series have consistent operation, i.e. a user who has learned to use one device can also quickly operate another device from the series.
Data Loggers, Recorders, Current Sensors
LCR and Impedance Measurement
Battery Testing for the Technologies of Today
Batteries play a central role in current technology. Whether in e-mobility, modern communications or the IoT, batteries are hugely important because they secure the power supply for these devices. In development, industrial production to everyday use in critical areas, batteries need to be measured, characterized, tested and monitored.
HIOKI has therefore placed one of its product focuses in the area of highly reliable an accurate battery testing. Thanks to devices from HIOKI, for example, battery diagnosis times can be reduced by about 60% with the required high accuracy. HIOKI devices help to test lithium-ion batteries: Test of insulation resistance, OCV/open circuit voltage, or internal resistance, and more.
Power Analysis for Efficient, Safe Energy Supplies
Efficiency, safety and the quality of energy supply play an enormously important role today in a time when sustainability and economy in energy consumption are essential. The power of an electrical system is the product of voltage and current (P=U*I). However, it is not quite as simple as in DC systems in practice, because here usually one has to deal with and analyze AC quantities, often even in complex multiphase systems, etc. Power analyzers are used here, which can measure or determine many other parameters in addition to voltage, current and power, including, for example, apparent and reactive power, phase angle, ripple factors and even harmonics.
Comparison HIOKI Power Analyzers Main Units
Model | ▸PW8001+U7005 | ▸PW8001+U7001 | ▸PW6001 | ▸PW3390 | |
Applications | Measurement of SiC and GaN inverters and reactor/transformer loss | Measurement of high-efficiency IGBT inverters and solar inverters | Measurement of high-efficiency IGBT inverters | Balance of high accuracy and portability | |
Measurement parameters | |||||
Measurement frequency band | DC, 0.1 Hz...5 MHz | DC, 0.1 Hz...1 MHz | DC, 0.1 Hz...2 MHz | DC, 0.5 Hz...200 kHz | |
Basic accuracy for 50/60 Hz power | ±(0.01% of reading + 0.02% of range) | ±(0.02% of reading + 0.05% of range) | ±(0.02% of reading + 0.03% of range) | ±(0.04% of reading + 0.05% of range) | |
Accuracy for DC power | ±(0.02% of reading + 0.03% of range) | ±(0.02% of reading + 0.05% of range) | ±(0.02% of reading + 0.05% of range) | ±(0.05% of reading + 0.07% of range) | |
Accuracy for 10 kHz power | ±(0.05% of reading + 0.05% of range) | ±(0.2% of reading + 0.05% of range) | ±(0.15% of reading + 0.1% of range) | ±(0.2% of reading + 0.1% of range) | |
Accuracy for 50 kHz power | ±(0.15% of reading + 0.05% of range) | ±(0.4% of reading + 0.1% of range) | ±(0.15% of reading + 0.1% of range) | ±(0.4% of reading + 0.3% of range) | |
Number of power measurement channels | 1 to 8 channels with U7001 and/or U7005 | 1 to 6 channels | 4 channels | ||
Voltage, current ADC sampling | 18 bit, 15 MHz | 16 bit, 2.5 MHz | 18 bit, 5 MHz | 16 bit, 500 kHz | |
Voltage range | 6/15/30/60/150/300/600/1500 V | 6/15/30/60/150/300/600/1500 V | 15/30/60/150/300/600/1500 V | ||
Current range | 100 mA...2000 A (6 ranges, based on sensor) | Probe 1: 100 mA...2000 A (6 ranges, based on sensor); probe 2: 100/200/500 mV/1/2/5 V |
Probe 1: 100 mA...2000 A (6 ranges, based on sensor); probe 2: 100/200/500 mV/1/2/5 V |
100 mA...8000 A (6 ranges, based on sensor) | |
Common-mode voltage rejection ratio | 50/60 Hz: 120 dB or greater; 100 kHz: 110 dB or greater |
50/60 Hz: 100 dB or greater; 100 kHz: 80 dB typ. |
50/60 Hz: 100 dB or greater; 100 kHz: 80 dB typ. |
50/60 Hz: 80 dB or greater | |
Temperature coefficient | 0.01%/°C | 0.01%/°C | 0.01%/°C | ||
Voltage input method | Photoisolated input,resistor voltage division | Isolated input, resistor voltage division | Photoisolated input, resistor voltage division | Isolated input, resistor voltage division | |
Current input method | Isolated input from current sensor | Isolated input from current sensor | Isolated input from current sensor | ||
External current sensor input | Yes (ME15W) | Yes (ME15W, BNC) | Yes (ME15W, BNC) | Yes (ME15W) | |
Power supplied to external current sensor | Yes | Yes | Yes | ||
Data update rate | 10/50/200 ms | 10/50/200 ms | 50 ms | ||
Voltage input | |||||
Maximum input voltage | 1000 V, ±2000 Vpeak | 1000 VAC, 1500 VDC, ±2000 Vpeak | 1000 V, ±2000 Vpeak (10 ms) | 1500 V, ±2000 Vpeak | |
Maximum rated line-to-ground voltage | 600 V CAT III 1000 V CAT II |
600 VAC/1000 VDC CAT III 1000 VAC/1500 VDC CAT II |
600 V CAT III 1000 V CAT II |
600 V CAT III 1000 V CAT II |
|
Analysis | |||||
Number of motor analysis channels | Maximum 4 motors (option) | Maximum 2 motors (option) | Maximum 1 motor (option) | ||
Motor analysis input format | Analog DC, frequency, pulse | Analog DC, frequency, pulse | Analog DC, frequency, pulse | ||
Function | |||||
Current sensor phase shift calculation | Yes (auto) | Yes | Yes | ||
Harmonics measurement | Yes (8, for each channel) | Yes (6, for each channel) | Yes | ||
Maximum harmonics analysis order | 500th | 100th | 100th | ||
Harmonics synchronization frequency range | 0.1 Hz...1.5 MHz | 0.1 Hz...1 MHz | 0.1 Hz...300 kHz | 0.5 Hz...5 kHz | |
IEC harmonics measurement | Yes | Yes | - | ||
IEC flicker measurement | Yes | - | - | ||
FFT spectrum analysis | Yes (DC...4 MHz) | Yes (DC...1 MHz) | Yes (DC...2 MHz) | Yes (DC...200 kHz) | |
User-defined calculations | Yes | Yes | - | ||
Delta conversion | Yes (Δ-Y, Y-Δ) | Yes (Δ-Y, Y-Δ) | Yes (Δ-Y) | ||
D/A output | Yes (option) 20 channels (waveform output, analog output) | Yes (option) 20 channels (waveform output, analog output) | Yes (option) 16 channels (waveform output, analog output) | ||
General | |||||
Display | 10.1"/25,7 cm WVGA TFT color LCD, touch screen | 9"/22.9 cm WVGA TFT color LCD, touch screen | 9"/22.9 cm WVGA TFT color LCD | ||
Interfaces | USB 2.0 (ext. storage medium), LAN (100BASE-TX, 1000BASE-T), GPIB, RS232C (max. 230,400 bps), optical link (option), CAN or CAN FD (option) | USB 2.0 (ext. storage medium), LAN (100BASE-TX, 1000BASE-T), GPIB, RS232C (max. 230,400 bps), optical link | USB 2.0 and CF card (ext. storage medium), LAN (10BASE-T, 100BASE-TX), RS232C (max. 38,400 bps) | ||
External control | Yes | Yes | Yes | ||
Synchronization of multiple instruments | Yes (up to 4 instruments) | - | Yes (up to 8 instruments) | ||
Dimensions (mm) | 430 x 221 x 361; 14 kg | 430 x 177 x 450; 14 kg | 340 x 170 x 156; 4.6 kg |