Benefits of the PW6001 Motor and Inverter Efficiency Power Analyzer

  • Measure high-efficiency IGBT inverters and analyze motors.
  • True frequency analysis with high-speed 5 MS/s 18-bit sampling.
  • Wide band, high stability for measuring electrical power from DC to inverter frequencies.

HIOKI PW6001 High Precision Power Analyzer DC, 0.1 Hz - 2 MHz, 3P4W

The HIOKI PW6001 is a high-precision and high-accuracy benchtop power meter and power analyzer for measuring single to three-phase lines. The PW6001 features wide band and high stability for measuring electrical power from DC to inverter frequencies, providing maximum of 6 or optional up to 12 channels to support single- and three-phase inverter motor system measurements and next generation devices such as silicon-carbide (SiC) inverters.

  • 6 channels, DC or 1P2W to 3P4W.
  • Exclusive current sensor phase shift function lets you maintain accuracy even in high frequency, low power factor applications.
  • Basic accuracy of ±0.02% for power measurement (PW6001 accuracy only; instrument delivers accuracy of ±0.07% even after the current sensor accuracy has been added).
  • High noise resistance and stability (80 dB/100 kHz CMRR, ±0.01%/°C temperature characteristics).
  • Accurate measurement even when the load is characterized by large fluctuations; TrueHD 18-bit resolution.
  • 10 ms data refresh while maintaining maximum accuracy.
  • DC accuracy of ±0.07%.
  • Wide frequency bandwidth of DC, or 0.1 Hz to 2 MHz.
  • Achieve true frequency analysis with high-speed 5 MS/s sampling (18 bit).
  • Synchronize two 6-channel units for up to 12 channels in real time (using optional optical connection cable).
  • Special triggers to enable waveform analysis and motor analysis without the need for an oscilloscope.
  • Wideband harmonic analysis up to the 100th order with a 1.5 MHz band.
  • Send measured values to HIOKI data loggers using a Bluetooth wireless technology compatible adapter (LR8410 Link-compatible products).

Model Overview

ModelHIOKI PW6001
Measurement linesDC, 1-phase-2-wire, 1-phase-3-wire, 3-phase-3-wire, 3-phase-4-wire
Max. channelsMax. 6; each input unit provides 1 channel for simultaneous voltage and current input (voltage measurement unit: Photoisolated input, resistance voltage divider, current measurement unit: Isolated input from current sensor)
Measurement frequency bandDC, 0.1 Hz...2 MHz
Data update ratePower measurement: 10 / 50 / 200 ms; harmonic measurement 200 ms (IEC standard mode), 50 ms (wideband mode
Accuracy (50 Hz/60 Hz)0.02% of reading + 0.03% of range (active power)
Measurement rangeVoltage: 6...1500 V, 8 ranges; current range (probe 1): 400 mA...1 kA (depends on current sensor); current range (probe 2): 100 mA...50 kA (depends on current sensor); power range: 2.40000 W...4.50000 MW (depends on combination of voltage and current range); frequency range: 0.1 Hz...2 MHz
Measurement parametersVoltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk);
harmonic measurement: Harmonic active power, select calculation order; from 2nd to 100th order;
waveform recording: Voltage and current waveforms/motor pulse: Always 5 MS/s;
motor waveforms: Always 50 kS/s, 16 bit;
motor analysis (PW6001-11 to -16 only): Voltage, torque, rotation, frequency, slip, or motor output
InterfaceUSB (memory), LAN/Ethernet, GPIB, RS232C (for communication/LR8410 link), external control, synchronization control; Bluetooth (logger)
Power supply100...240 VAC, 50/60 Hz, max. 200 VA
Dimensions (mm)430 x 177 x 450; 14 kg (PW6001-16)

Included: Power cord, instruction manual, D-sub connector (PW6001-1x only).

Versions and Options

ModelDescription
PW6001-01Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 1 channel
PW6001-02Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 2 channels
PW6001-03Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 3 channels
PW6001-04Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 4 channels
PW6001-05Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 5 channels
PW6001-06Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 6 channels
PW6001-11Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 1 channel, with D/A output interface and motor analysis option
PW6001-12Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 2 channels, with D/A output interface and motor analysis option
PW6001-13Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 3 channels, with D/A output interface and motor analysis option
PW6001-14Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 4 channels, with D/A output interface and motor analysis option
PW6001-15Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 5 channels, with D/A output interface and motor analysis option
PW6001-16Power analyzer, ±0.02% accuracy, wide-band DC, 0.1 Hz...2 MHz, DC or 1P2W to 3P4W measurements, 6 channels, with D/A output interface and motor analysis option
▸PW9100A-3Power analyzers direct input box, AC/DC current box, direct current measurement option for PW8001/6001/PW3390, wide-band DC...3.5 MHz, 50 AAC/DC rated input, 0.04 V/A output, 3 channels, automatic sensor detection