Keysight E5061B Vector Network Analyzer up to 3GHz
starting €
28.537,39
including VAT
free shipping (Germany)
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads
Benefits of the E5061B 2-Port VNA up to 1.5 GHz or 3 GHz
- 2-Port, 50 or 75 Ω VNA up to 3 GHz.
- 3 option sets available with upgrade possibilities (transmission/reflection, S-parameter, LF-RF network analyzer).
- Variety of calibration types available.
Keysight E5061B Vector Network Analyzer up to 3 GHz
The Keysight E5061B are 2-port VNAs (Vector Network Analyzer) up to 3 GHz. Three option sets are available: Economy models with transmission/reflection test set, versions with S-parameter test set, and LF-RF network analyzer with DC bias source/S-parameter test set and gain-phase ports.
- 2-Port, 50 or 75 Ω VNA.
- Frequency ranges up to 1.5 or 3 GHz.
- Low frequency coverage down to 5 Hz.
- Built-in DC bias source.
- Impdeance analysis capabilities.
- Power integrity measurements.
- 3 option sets available with upgrade possibilities:
- Economy transmission/reflection test set.
- S-parameter test set.
- LF-RF network analyzer with DC bias source/S-parameter test set and gain-phase ports.
- 26.4 cm wide high-resolution multi touch-screen LCD.
- LAN/Ethernet, USB, and GPIB/IEEE488 interfaces.
Model Overview
Model/option | E5061B-115 | E5061B-117 | E5061B-135 | E5061B-137 | E5061B-215 | E5061B-217 | E5061B-235 | E5061B-237 | E5061B-3L3 | E5061B-3L4 | E5061B-3L5 |
Economy transmission/reflection test set | S-parameter test set | LF-RF network analyzer with DC bias source/S-parameter test set and gain-phase ports | |||||||||
Ports | 2 | ||||||||||
Frequency | 100 kHz...1.5 GHz | 100 kHz...3 GHz | 100 kHz...1.5 GHz | 100 kHz...3 GHz | 5 Hz...500 MHz | 5 Hz...1.5 GHz | 5 Hz...3 GHz | ||||
Resolution | (Test port output/source) 1 mHz | ||||||||||
System impedance | 50 Ω | 75 Ω | 50 Ω | 75 Ω | 50 Ω | 75 Ω | 50 Ω | 75 Ω | 50 Ω | 50 Ω | 50 Ω |
Dynamic range | 120 dB (detailed see datasheet) | ||||||||||
Trace noise | 0.005 dBRMS (spec.) | ||||||||||
Stability | 0.01 dB/°C | ||||||||||
Gain phase measurement | - | - | Source range 5 Hz...30 MHz, resolution 1 mHz | ||||||||
DC bias | - | - | Output port 1, LF out; range 0...±40 V (100 mA max.); resolution 1 mV ±(0...10 V)/4 mV ±(10...40 V) | ||||||||
IF bandwidth settings | Range 1 Hz...300 kHz, nominal settings are: 1, 1.5, 2, 3, 4, 5, 7 | ||||||||||
Number of points per traces | 2 to 1,601 | ||||||||||
Key software capability | Time domain analysis, wireless power transfer analysis, impedance analysis | ||||||||||
Calibration types available | Response: Simultaneous magnitude and phase correction of frequency response errors for either reflection or transmission measurements. Response and isolation: Compensates for frequency response and crosstalk errors of transmission measurements. Enhanced response: Compensates for frequency response and source match errors. One-port calibration: Compensates for directivity, frequency response and source match errors. Full 2-port calibration (option 215, 235, 217, 237, 3L3, 3L4, 3L5): Compensates for directivity, source match, reflection tracking, load match, transmission tracking and crosstalk. Crosstalk calibration can be omitted. Interpolated error correction: With any type of accuracy enhancement applied, interpolated mode recalculates the error coefficients when the test frequencies are changed. The number of points can be increased or decreased and the start/stop frequencies can be changed. Velocity factor: Enter the velocity factor to calculate the equivalent physical length. Reference port extension: Redefine the measurement plane from the plane where the calibration was done. | ||||||||||
Display | 10.4"/26.4 cm multi touch-screen LCD, resolution XGA (1024x768) | ||||||||||
Interfaces | LAN/Ethernet, USB, GPIB/IEEE488; SCPI-compatible; handler-I/O | ||||||||||
Dimensions (mm) | 433 x 222 x 297; depending on integrated options approx. 13.1 to 14.4 kg |
Keysight E506x Series Model Comparison
Model | ▸E5061B | ▸E5063A |
Frequency | 100 kHz...1.5 GHz 100 kHz...3 GHz or 5 Hz...0.5 GHz 5 Hz...1.5 GHz 5 Hz...3 GHz | 100 kHz...0.5 GHz 100 kHz...1.5 GHz 100 kHz...3 GHz 100 kHz...4.5 GHz 100 kHz...6.5 GHz 100 kHz...8.5 GHz 100 kHz...14 GHz 100 kHz...18 GHz |
Test ports | 2 port, 50/75 Ω or 2-port gain-phase | 2 port, 50 Ω |
System dynamic range (10 Hz IFBW) | 120 dB | 117 dB |
Trace noise | 0.005 dBRMS (3 kHz IFBW) | 0.005 dBRMS (70 kHz IFBW) |
Cycel time (typ. 2-port cal, max. IFBW, 201 pts) | 21 ms | 19 ms |
Source power | -45...0 dBm | -20...0 dBm |
Temperature stability (typ.) | 0.01 dB/°C | 0.01 dB/°C |
Connectivity | LAN/Ethernet, USB, GPIB, Handler I/O | LAN/Ethernet, USB, GPIB, Handler I/O |
Impedance analysis | ✓ | - |
Wireless power transfer analysis | ✓ | ✓ |
Time domain analysis | ✓ | ✓ |
PCB test wizard | - | ✓ |
Material properties measurements | ✓ (N1500A material measurement suire requred) | ✓ (N1500A material measurement suire requred) |
Upgrade to higher frequency | ✓ | ✓ |
Agilent's Electronic Measurement Group is now Keysight Technologies.