Benefits of the SDS2104X-HD, SDS2204X-HD, and SDS2354X-HD High-Accuracy Mixed-Signal Oscilloscopes

  • True 12-bit high resolution for more signal details.
  • Low noise floor and high accuracy.
  • 100, 200, 350, or 500 MHz1) bandwidth and advanced features.

Siglent SDS2000X HD Series 12 bit High Resolution Oscilloscopes

With the SDS2000X-HD Siglent enhances the commen oscilloscope ADC resolution of 8 bit to true 12 bit. This makes resolution accuracy 16 times higher than on common 8-bit oscilloscopes and shows more signal details. The oscilloscopes have bandwidths up to 350 MHz, upgradeable to 500 MHz1). Other partly standard or optional features are MSO-capability (mixed-signal/logic analyzer), a built-in arbitraty waveform generator, 2-Mpts hardware-accelerated FFT, Bode plot function, serial bus trigger and decode (many as standard, additional ones as software options), and more. The wide and clear 10.1"/25.65 cm TFT LCD with multi-touch gesture touch screen makes the devices easy-to-use.

  • High sampling rate with 12-bit ADCs (enhanced resolution to 15 bit). Resolution accuracy 16 times higher than on common 8-bit oscilloscopes.
  • Front ends with lower noise floor: 70 µVRMS at 500 MHz bandwidth and 0.5% DC gain accuracy.
  • "Cleaner"/"clearer" waveform display showing more signal details and allowing more accurate waveform measurements.
  • 100 MHz, 200 MHz, or 350 MHz bandwidth, upgradeable to 500 MHz1).
  • 100,000 Wfms/s waveform capture rate.
  • Deep record length of 200 Mpts.
  • Automatic measurements on more than 50 parmeters.
  • History waveform playback.
  • Mixed-signal (MSO) function.
  • Additional features and options: Bode plot; hardware-accelerated FFT up to 2 Mpts; power analysis; serial bus trigger and decode.
  • 10.1"/25.65 cm TFT LCD with capacitive multi-touch gesture touch screen.
  • Interfaces: USB Host and Device, Ethernet/LAN.
  • Built-in web-server supports remote control.
  • Applications:
    Measuring high-precision sensors and actuators.
    Medical equipment.
    Laser pulses.
    RF signals/modulated signals.
    Power measurement.
    and more.

Model Overview

ModelSDS2104X-HD
EOL/obsolete
SDS2204X-HDSDS2354X-HD
Analog channels4
Bandwidth100 MHz200 MHz350 MHz
Resolution12 bit; HiRes/ERES 3 bit hardware-based
Sample rate2 GS/s (interleaving), 1 GS/s (non-interleaving)
Memory depth200 Mpts
Waveform capture rate100,000 Wfms/s (normal); 500,000 Wfms/s (sequence mode)
AccuracyDC gain 0.5 mV/Div...4.95 mV/Div: ±1.5%; 5 mV/Div...10 V/Div: ±0.5%
Time base ±2 ppm (initial); ±0.5 ppm (1st year aging); ±3 ppm (20-year aging)
Noise floor70 µVRMS at 500 MHz
SFDR≥45 dBc
Channel-to-channel isolation>60 dBc, <500 MHz
>70 dBc, <350 MHz
TriggerEdge, slope, pulse, window, runt, interval, dropout, pattern, video, qualified, nth edge, delay, setup/hold time, serial;
serial trigger and decode standard: I2C, SPI, UART, CAN, LIN; optional: CAN FD, FleyRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only)
SequenceUp to 80,000 segments
HistoryUp to 80,000 frames
Digital channels (MSO option)16; max. 500 MS/s max. waveform capture rate; record lenght up to 50 Mpts (additional MSO probes required)
Additional featuresBode plot; hardware-accelerated FFT up to 2 Mpts, 7-digits counter, digital multimeter
Arbitrary waveform generatorBuilt-in, 25 MHz (software option); 125 MS/s sample rate, 16 kpts waveform memory
Display10.1"/25.65 cm TFT-LCD capacitive touch-screen with multi-touch gestures
InterfacesUSB Host and Device, Ethernet/LAN; built-in web-server

Included: Siglent SDS 2104X HD, 2204X HD, or 2354X HD, power cord, USB cable, 4x passive probe, quick start guide, certificate of calibration, wireless mouse.

Options and Accessories

ModelDescription
SDS2000HD-FG25 MHz built-in function generator option (software)
SPL2016MSO logic probe, 16 channel
SDS2000HD-PAPower analysis: Power quality, current harmonics, inrush current, switching loss, slew rate, modulation, output ripple, turn on/off, transient response, PSRR, efficiency
DF2001ADeskew fixture for voltage and current probe
SDS2000HD-I2SI2S trigger and decode (software)
SDS2000HD-1553BMIL-STD-1553B trigger and decode (software)
SDS2000HD-FlexRayFlexRay trigger and decode (software)
SDS2000HD-CANFDCAN FD trigger and decode (software)
SDS2000HD-SENTSENT trigger and decode (software)
SDS2000HD-ManchManchester decode (software)
SDS2000HD-BW1T2Upgrade bandwidth from 100 MHz to 200 MHz
SDS2000HD-BW1T3Upgrade bandwidth from 100 MHz to 350 MHz
SDS2000HD-BW1T5Upgrade bandwidth from 100 MHz to 500 MHz1)
SDS2000HD-BW2T3Upgrade bandwidth from 200 MHz to 350 MHz
SDS2000HD-BW2T5Upgrade bandwidth from 200 MHz to 500 MHz1)
SDS2000HD-BW3T5Upgrade bandwidth from 350 MHz to 500 MHz1)

1) Note: 500 MHz available only when ADCs are in interleaved mode (2 GS/s). When ADCs work in non interleaved mode, bandwidth is limited to 350 MHz.