Copper Mountain S Series 2-Port VNA up to 44GHz
Benefits of the Copper Mountain S Series 2-Port USB PC VNA
- High output power of +10 dBm.
- Inbuilt options like time domain with gating, vector mixer calibration measurement, frequency offset mode etc.
- Wide frequency bandwidth from 9 kHz to 44 GHz with excellent dynamic range of 135 dB.
Copper Mountain S Series 2-Port VNA up to 44 GHz
Models Copper Mountain S7530, S5045, S5065, S5085, S5180B, S5243
The Copper Mountain compact series S5000/S7000 VNAs (vector network analyzers) delivers lab grade performance in a compact package, with all the features engineers have come to expect included standard in the software.
These portable VNAs can be battery powered and used in the field, in the laboratory, and in production testing. The devices can be integrated into a production test system via manufacturing test plugin.
The Copper Mountain compact series S5000/S7000 VNA includes an RF measurement module and the S2 software application (depending on version optional accessory) which runs on Windows or Linux operating system on a PC, laptop, tablet, or x86 board computer connecting to the measurement hardware via USB interface. The S2 software can be installed on multiple computers, making it easy to share the use of the analyzer measurement module.
- Frequency range up to 1.3 GHz, 3.0 GHz, 4.8 GHz, 6.5 GHz, 8.5 GHz, 18 GHz, or 44 GHz.
- Measured parameters S11, S21, S12, S22.
- Sweep types: Linear frequency, log frequency, segment, power sweep.
- Impedance 50 Ω 75 Ω.
Applications
The Copper Mountain Technologies compact series VNAs are designet for applications that include RF component design and testing, on-wafer probing, field testing, insertion loss measurement, distance to fault measurements, antenna matching, quality control, material measurements, and many others.
Model Overview
Replacement models for the obsolete versions: ▸SC-VNA series.
Model | S7530 EOL/obsolete | S5045 EOL/obsolete | S5048 EOL/obsolete | S5065 EOL/obsolete | S5085 EOL/obsolete | S5180B | S5243 |
Ports | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Frequency range | 20 kHz...3.0 GHz | 9 kHz...4.5 GHz | 20 kHz...4.8 GHz | 9 kHz...6.5 GHz | 9 kHz...8.5 GHz | 100 kHz...18 GHz | 10 MHz...44 GHz |
Measured parameters | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 |
Sweep types | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep |
Dynamic range (10 Hz IFBW) | 75 dB/typ. 100 dB (20...300 kHz) 120 dB/typ. 123 dB (300 kHz...3.0 GHz) | 85 dB/typ. 100 dB (9 kHz...300 kHz) 125 dB/typ. 130 dB (300 kHz...4.5 GHz) | 75 dB/tpy. 100 dB (20 kHz...300 kHz) 120 dB/typ. 123 dB (300 kHz...4.8 GHz) | 85 dB/typ. 100 dB (9 kHz...300 kHz) 125 dB/typ. 130 dB (300 kHz...6.5 GHz) | 85 dB/typ. 100 dB (9...300 kHz) 125 dB/typ. 130 dB (300 kHz...4.8 GHz) 120 dB/typ. 125 dB (4.8...8.0 GHz) 115 dB/typ. 120 dB (8.0...8.5 GHz) | 100 dB/typ. 120 dB (100 kHz...1 MHz); 130 dB/typ. 133 dB (1 MHz...6.5 GHz); 127 dB/typ. 130 dB (6.5...8.5 GHz); 125 dB (8.5...16 GHz); 121 dB (16...18 GHz) | 135 dB/typ. 140 dB (10 MHz...8 GHz) 125 dB/typ. 130 dB (8...44 GHz) |
Measurement speed/measurement time per point | 250 µs | 70 µs | 200 µs | 70 µs | 70 µs | 24 µs | 15 µs |
Output power adjustment rate | -50...+5 dBm | -55...+5 dBm | -50...+5 dBm | -50...+5 dBm | -55...+5 dBm | -45...+10 dBm (100 kHz...16 GHz); -45...+6 dBm (16...18 GHz | -50...0 dBm |
Measurement points | up to 200,001 | up to 200,001 | up to 200,001 | up to 200,001 | up to 200,001 | up to 200,001 | up to 500,001 |
Impedance | 75 Ω | 50 Ω | 50 Ω | 50 Ω | 50 Ω | 50 Ω | 50 Ω |
Interface | USB 2.0 (USB type B) | USB 2.0 (USB type B) | USB 2.0 (USB type B) | USB 2.0 (USB type B) | USB 2.0 (USB type B) | USB 2.0 (USB type B) | USB 2.0 (USB type B) |
Power supply | External power adaptor | External power adaptor | External power adaptor | External power adaptor | External power adaptor | External power adaptor | External power adaptor |
Recommended cal. kits | ACM4000T, F7511 | N611, N612, S911T | ACM2506, N611, N612, S911T | ACM2506, N611, N612, S911T | ACM2509, N611, N612, S911T | ACM2520, N1801, S2611 | Z5411, T4311 |
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 accredited, traceable calibration certificate and uncertainties is available and needs to be specified at time of order.