Copper Mountain SC Series 2-Port Most Advanced VNAs up to 9GHz
Benefits of the Copper Mountain SC Series 2-Port USB PC VNAs
- High dynamic range up to 140 dB.
- Wide output power range -45...+15 dBm.
- Up to 500,001 measurement sweep points with a excellent measurement speed of 16 µs per point.
Copper Mountain SC Series 2-Port Most Advanced VNA up to 9 GHz
Models Copper Mountain SC5065, SC5090
The Copper Mountain SC VNA series are compact, 2-port vector network analyzer with an excellent dynamic range, fast measurement speed and a high output power, with the maximum standard software feature set.
SC series VNAs includes an RF measurement module (hardware) and S2 software (depending on version optional accessory) for Windows or Linux operating system on a PC, laptop, tablet, or x86 board computer connecting to the measurement hardware via USB interface. S2 software can be installed on multiple computers, making it easy to share the use of the analyzer measurement module.
- Frequency range up to 6.5 GHz or 9 GHz.
- Measured parameters S11, S21 or S11, S21, S12, S22.
- Sweep types: Linear frequency sweep and logarithmic frequency sweep are performed with fixed output power. Linear power sweep is performed at a fixed frequency.
- Impedance 50 Ω.
Applications
Design, development, verification and manufacturing of components, devices, and various equipment for modern industrial needs. Relevant industries include telecommunications, automotive, IoT, aerospace, and medical devices, among many others.
Model Overview
Model | SC5065 | SC5090 |
Ports | 2 | 2 |
Frequency range | 300 kHz...6.5 GHz | 300 kHz...9 GHz |
Measured parameters | S11, S21, S12, S22 | S11, S21, S12, S22 |
Sweep types | Linear frequency sweep and logarithmic frequency sweep are performed with fixed output power. Linear power sweep is performed at a fixed frequency. | Linear frequency sweep and logarithmic frequency sweep are performed with fixed output power. Linear power sweep is performed at a fixed frequency. |
Dynamic range (10 Hz IFBW) | 125 dB (300 kHz...1 MHz) 135 dB/typ. 138 dB (1...5 MHz) 140 dB (5 MHz...4 GHz) 138 dB/typ. 140 dB (4.0...6.5 GHz) | 125 dB (300 kHz...1 MHz) 135 dB/typ. 138 dB (1...5 MHz) 140 dB (5 MHz...4 GHz) 138 dB/typ. 140 dB (4.0...6.5 GHz) 133 dB/typ. 136 dB (6.5...8.0 GHz) 125 dB/typ. 130 dB (8 ...9 GHz) |
Measurement speed/measurement time per point | 16 µs | 16 µs |
Output power adjustment rate | -45...+15 dBm | -45...+15 dBm |
Measurement points | up to 500,001 | up to 500,001 |
Interface | USB 2.0 (USB type B) | |
Power supply | External power adaptor | |
Recommended accessories | Autom. cal module ACM2506 Cal. kits N911, N912, S911T Cables and adaptors 2x C50NMNM.X, 2x C50NMNM.X + NF50, 2x C50SMNM.X Torque wrench TW-S, TW-N | Autom. cal module ACM2509 Cal. kits N911, N912, S911T Cables and adaptors 2x C50NMNM.X, 2x C50NMNM.X + NF50, 2x C50SMNM.X Torque wrench TW-S, TW-N |