Files/Downloads
Benefits of the Premier2800 Series Safety Testers
- Depending on model testers for AC/DC withstanding, insulation resistance, grund bond.
- Meet the test requirements of a variety of safety standards.
- 200 VAAC test capacity.
Eaton Sefelec Premier2800 Series Electrical Safety Testers
The Eaton Sefelec Premier2800 series electrical safety testers are devices with high durability and multiple user-protection design. They meet the test requirements of a variety of safety standards, such as IEC, EN, UL, CSA, GB, JIS, and others, for electronic products and components. The Premier8200 series includes a total of 4 safety testers (see table below).
- 200 VAAC test capacity.
- Hipot up to 5 kVAC/6 kVDC.
- Insulation up to 1000 VDC.
- Manual/auto mode.
- Function key for quick selecting.
- High intensity flash for caution and status indication.
- Safety interlock function.
- Zero crossing turn-on operation.
- Controllable ramp-up time.
- True RMS current measurement.
- High resolution: 1 µA for measuring current, 2 V for setting voltage.
- PWM switching amplifier to enhance the power efficiency and reliable testing.
- Max. 100 memory block for test condition (step) setting. Each step can be named individually.
- Remote terminal on the front panel for "start" and "stop" control by external.
- 240x64 dot matrix LCD.
- Interfaces: RS232C, USB device, signal I/O, and GPIB (optional).
- Applications include safety testing of electrical products in manufacturing (power cords, home appliances, information technology equipment, medical equipment), quality assurance verification, safety standard compliance pre-qualification in R&D.
- Dimensions (mm): 330 x 150 x 460; approx. 15...19 kg depending on version.
Model Overview
Model | Premier2804 | Premier2803 | Premier2802 | Premier2801 |
AC withstanding | Yes | Yes | Yes | Yes |
Output voltage range 0.100...5.000 kVAC; max. rated load 200 VA (5 kV/40 mA); output voltage waveform/frequency: Sine, 50 Hz/60 Hz selectable; current measurement range 0.001...40.0 mA; RAMP (ramp-up time) 0.1...999.9 s; TIMER (test time) OFF, 0.5...999.9 s; GND: RETURN/GUARD | ||||
DC withstanding | Yes | Yes | Yes | - |
Output voltage range 0.100...6.000 kVDC; max. rated load 50 W (5 kV/10 mA); current maesurement range 0.001...10.0 mA; RAMP (ramp-up time) 0.1...999.9 s; TIMER (test time) OFF, 0.5...999.9 s; GND: RETURN/GUARD | ||||
Insulation resistance | Yes | Yes | - | - |
Output voltage 50...1000 VDC; resistance measurment range 1...9500 MΩ; RAMP (ramp-up time) 0.1...999.9 s; TIMER (test time) OFF, 1...999.9 s; GND: GUARD (fix) | ||||
Ground bond tests | Yes | - | - | - |
Output current 03.00...30.00 AAC; resistance measurement range 10...650.0 mΩ; TIMER (test time) 0.5...999.9 s; testing method: Four terminal | ||||
Memory | Single step memory MANU: 100 blocks; automatic testing memory AUTO: 100 blocks, menu per AUTO: 16 | |||
Interfaces | RS232C (standard), USB (standard), IEEE488/GPIB (optional), remote terminal (front, standard), signal I/O (standard) | |||
Display | 240 x 64 ice blue dot matrix LCD | |||
Dimensions (mm) | 330 x 150 x 460; approx. 15 kg max. for Premier2803/2802/2801; approx. 19 kg max. for Premier2804 |