Rohde&Schwarz NPA Power Analyze

New
starting 1.927,80
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the NPA Series Power Analyzers up to 12 kW

  • Power analyzers for AC/DC load or standby current characterization.
  • Power ranging from 50 µW to 12 kW, bandwidth from DC to 100 kHz.
  • Sampling rate 500 kS/s.

Rohde&Schwarz NPA Power Analyzer

Models R&S NPA101, NPA501, NPA501-G, NPA701, NPA701-G up to 500 kS/s

The Rohde&Schwarz NPA series are a family of compact power analyzers. The testers are designed for AC/DC load or standby current characterization, with a basic accuracy of 0.05%. These analyzers facilitate power measurements across a broad spectrum, ranging from 50 µW to 12 kW, enabling signal acquisition from DC to 100 kHz at an impressive sampling rate of 500 kS/s. Beyond numerical displays of 26 critical parameters, the instruments offer optional graphical features and compliance protocols aligned with industry standards depending upon the chosen model.

  • Compact power analyzers for AC/DC load or standby current characterization.
  • Basic accuracy 0.05%.
  • Power ranging from 50 µW to 12 kW.
  • Bandwidth from DC to 100 kHz.
  • Sampling rate 500 kS/s.
  • Numerical displays of 26 critical parameters, as well as optional graphical features and compliance protocols aligned with industry standards.
  • Basic measurements in voltage, current, power, and THD applications.
  • Advanced analysis, depending on version/options: Peak-to-peak value measurements, four BNC ports for analog and digital inputs and outputs, graphical functions including waveform and trend chart, inrush function, harmonics recording, and a PASS/FAIL feature, ideal for production testing.
  • Inclusion of additional sensor input for connecting a current clamp or shunt.
  • Top-tier model NPA701: Compliance tester, encompasses performance and compliance protocols such as IEC 62301, EN 50564, or EN 61000-3-2.
  • Connecting to the device under test is streamlined through an AC mains adapter like the NPA-Z1, where the DUT is seamlessly integrated.
  • Remote control via LAN/Ethernet or USB interface.
  • Free driver packages for LabVIEW and LabWindows/CVI.

Model Overview

ModelR&S NPA101R&S NPA501R&S NPA501-GR&S NPA701R&S NPA701-G
3657.0562.023657.0562.033657.0562.053657.0562.043657.0562.06
TypePower meterPower analyzerCompliance tester
Function overviewBasicP - active power (W)
S - apparent power (VA)
Q - reactive power (VAR)
PF - power factor (λ)
PHI - phase shift (φ)
FU - voltage frequency value (Hz)
FI - crrent frequency value (Hz)
FPLL - acquisition frequency (Hz)
URMS - RMS voltage (U RMS)
UAVG - average voltage (U AVG)
IRMS - RMS current (I RMS)
IAVG - average current (I AVG)
UTHD - total harmonic distortion U
ITHD - total harmonic distortion I
WHM, WHP, WH, AHM, AHP, AH - energy counter (integrator values)
Logging recording of measured values (CSV)
AdvancedUPPeak - maximum voltage (U PEAK)-
UMPeak - minimum voltage (U PEAK)-
IPPeak - maximum current (I PEAK)-
IMPeak - minimum current (I PEAK)-
PPPeak - maximum power (P PEAK)-
PMPeak - minimum power (P PEAK)-
Limit/PASS-FAIL - limit display-
Sensor input - input for current probe/external shunt-
DIN/AIN - digital/analog inputs and outputs (BNC)-
GraphicalHarmonics - bargraph of up to 50 harmonics-
Waveform - waveform display (displays one period of voltage, current or power)-
Trendchart - current and voltage displayed as a waveform-
Inrush - triggered display of waveform (single shot)-
Compliance evaluationIEC 62301 - standby standard--
EN 50564 - extended standby standard--
EN 61000-3-2 - harmonic current for EMC, CE approval--
BandwidthDC to 20 kHzDC to 100 kHzDC to 100 kHz
Voltagemax. 600 Vmax. 600 Vmax. 600 V
Currentmax. 20 Amax. 20 Amax. 20 A
Power range50 µW to 12 kW50 µW to 12 kW50 µW to 12 kW
Sample rate500 kS/s500 kS/s500 kS/s
Additional functionsLoggingPeak values, pass/fail function, grapical display, sensor input, analog/digital inputs/outputs, loggingPeak values, pass/fail function, grapical display, sensor input, analog/digital inputs/outputs, logging, compliance tests acc. to IEC 62301, EN 50564, and EN 61000-3-2
InterfacesUSB, Ethernet/LANUSB, Ethernet/LANUSB, Ethernet/LAN, GPIB/IEEE488USB, Ethernet/LANUSB, Ethernet/LAN, GPIB/IEEE488
DisplayColor TFT
Dimensions (mm)22 x 97 x 291; 3 kg
Replacement forR&S HMC8015(-G) and options R&S HOC151 (advanced analysis), R&S HOC152 (advanced I/O), R&S HOC153 (compliance test)

Test Adaptor Overview

ModelDescription
R&S NPA-Z13657.8911.02Test adaptor, EU socket, for R&S NPA power analyzer series (optional accessory)
R&S NPA-Z23657.8911.03Test adaptor, UK socket, for R&S NPA power analyzer series (optional accessory)
R&S NPA-Z33657.8911.04Test adaptor, US socket, for R&S NPA power analyzer series (optional accessory)
R&S NPA-Z43657.8911.05Test adaptor, CHN/AUS socket, for R&S NPA power analyzer series (optional accessory)