Benefits of the NPA Series Power Analyzers up to 12 kW
- Power analyzers for AC/DC load or standby current characterization.
- Power ranging from 50 µW to 12 kW, bandwidth from DC to 100 kHz.
- Sampling rate 500 kS/s.
Rohde&Schwarz NPA Power Analyzer
Models R&S NPA101, NPA501, NPA501-G, NPA701, NPA701-G up to 500 kS/s
The Rohde&Schwarz NPA series are a family of compact power analyzers. The testers are designed for AC/DC load or standby current characterization, with a basic accuracy of 0.05%. These analyzers facilitate power measurements across a broad spectrum, ranging from 50 µW to 12 kW, enabling signal acquisition from DC to 100 kHz at an impressive sampling rate of 500 kS/s. Beyond numerical displays of 26 critical parameters, the instruments offer optional graphical features and compliance protocols aligned with industry standards depending upon the chosen model.
- Compact power analyzers for AC/DC load or standby current characterization.
- Basic accuracy 0.05%.
- Power ranging from 50 µW to 12 kW.
- Bandwidth from DC to 100 kHz.
- Sampling rate 500 kS/s.
- Numerical displays of 26 critical parameters, as well as optional graphical features and compliance protocols aligned with industry standards.
- Basic measurements in voltage, current, power, and THD applications.
- Advanced analysis, depending on version/options: Peak-to-peak value measurements, four BNC ports for analog and digital inputs and outputs, graphical functions including waveform and trend chart, inrush function, harmonics recording, and a PASS/FAIL feature, ideal for production testing.
- Inclusion of additional sensor input for connecting a current clamp or shunt.
- Top-tier model NPA701: Compliance tester, encompasses performance and compliance protocols such as IEC 62301, EN 50564, or EN 61000-3-2.
- Connecting to the device under test is streamlined through an AC mains adapter like the NPA-Z1, where the DUT is seamlessly integrated.
- Remote control via LAN/Ethernet or USB interface.
- Free driver packages for LabVIEW and LabWindows/CVI.
Model Overview
Model | R&S NPA101 | R&S NPA501 | R&S NPA501-G | R&S NPA701 | R&S NPA701-G | ||
3657.0562.02 | 3657.0562.03 | 3657.0562.05 | 3657.0562.04 | 3657.0562.06 | |||
Type | Power meter | Power analyzer | Compliance tester | ||||
Function overview | Basic | P - active power (W) | ✓ | ✓ | ✓ | ||
S - apparent power (VA) | ✓ | ✓ | ✓ | ||||
Q - reactive power (VAR) | ✓ | ✓ | ✓ | ||||
PF - power factor (λ) | ✓ | ✓ | ✓ | ||||
PHI - phase shift (φ) | ✓ | ✓ | ✓ | ||||
FU - voltage frequency value (Hz) | ✓ | ✓ | ✓ | ||||
FI - crrent frequency value (Hz) | ✓ | ✓ | ✓ | ||||
FPLL - acquisition frequency (Hz) | ✓ | ✓ | ✓ | ||||
URMS - RMS voltage (U RMS) | ✓ | ✓ | ✓ | ||||
UAVG - average voltage (U AVG) | ✓ | ✓ | ✓ | ||||
IRMS - RMS current (I RMS) | ✓ | ✓ | ✓ | ||||
IAVG - average current (I AVG) | ✓ | ✓ | ✓ | ||||
UTHD - total harmonic distortion U | ✓ | ✓ | ✓ | ||||
ITHD - total harmonic distortion I | ✓ | ✓ | ✓ | ||||
WHM, WHP, WH, AHM, AHP, AH - energy counter (integrator values) | ✓ | ✓ | ✓ | ||||
Logging recording of measured values (CSV) | ✓ | ✓ | ✓ | ||||
Advanced | UPPeak - maximum voltage (U PEAK) | - | ✓ | ✓ | |||
UMPeak - minimum voltage (U PEAK) | - | ✓ | ✓ | ||||
IPPeak - maximum current (I PEAK) | - | ✓ | ✓ | ||||
IMPeak - minimum current (I PEAK) | - | ✓ | ✓ | ||||
PPPeak - maximum power (P PEAK) | - | ✓ | ✓ | ||||
PMPeak - minimum power (P PEAK) | - | ✓ | ✓ | ||||
Limit/PASS-FAIL - limit display | - | ✓ | ✓ | ||||
Sensor input - input for current probe/external shunt | - | ✓ | ✓ | ||||
DIN/AIN - digital/analog inputs and outputs (BNC) | - | ✓ | ✓ | ||||
Graphical | Harmonics - bargraph of up to 50 harmonics | - | ✓ | ✓ | |||
Waveform - waveform display (displays one period of voltage, current or power) | - | ✓ | ✓ | ||||
Trendchart - current and voltage displayed as a waveform | - | ✓ | ✓ | ||||
Inrush - triggered display of waveform (single shot) | - | ✓ | ✓ | ||||
Compliance evaluation | IEC 62301 - standby standard | - | - | ✓ | |||
EN 50564 - extended standby standard | - | - | ✓ | ||||
EN 61000-3-2 - harmonic current for EMC, CE approval | - | - | ✓ | ||||
Bandwidth | DC to 20 kHz | DC to 100 kHz | DC to 100 kHz | ||||
Voltage | max. 600 V | max. 600 V | max. 600 V | ||||
Current | max. 20 A | max. 20 A | max. 20 A | ||||
Power range | 50 µW to 12 kW | 50 µW to 12 kW | 50 µW to 12 kW | ||||
Sample rate | 500 kS/s | 500 kS/s | 500 kS/s | ||||
Additional functions | Logging | Peak values, pass/fail function, grapical display, sensor input, analog/digital inputs/outputs, logging | Peak values, pass/fail function, grapical display, sensor input, analog/digital inputs/outputs, logging, compliance tests acc. to IEC 62301, EN 50564, and EN 61000-3-2 | ||||
Interfaces | USB, Ethernet/LAN | USB, Ethernet/LAN | USB, Ethernet/LAN, GPIB/IEEE488 | USB, Ethernet/LAN | USB, Ethernet/LAN, GPIB/IEEE488 | ||
Display | Color TFT | ||||||
Dimensions (mm) | 22 x 97 x 291; 3 kg | ||||||
Replacement for | R&S HMC8015(-G) and options R&S HOC151 (advanced analysis), R&S HOC152 (advanced I/O), R&S HOC153 (compliance test) |
Test Adaptor Overview
Model | Description | |
R&S NPA-Z1 | 3657.8911.02 | Test adaptor, EU socket, for R&S NPA power analyzer series (optional accessory) |
R&S NPA-Z2 | 3657.8911.03 | Test adaptor, UK socket, for R&S NPA power analyzer series (optional accessory) |
R&S NPA-Z3 | 3657.8911.04 | Test adaptor, US socket, for R&S NPA power analyzer series (optional accessory) |
R&S NPA-Z4 | 3657.8911.05 | Test adaptor, CHN/AUS socket, for R&S NPA power analyzer series (optional accessory) |