Keysight InfiniiVision MSOX4000G MSO/Oscilloscopes up to 1.5GHz, 5GS/s
Benefits of the Keysight MSOX4000G Series Mixed-Signal Oscilloscopes with Touchscreen
- Multifunctional MSO, many options included as standard.
- Excellent ease of use with 12.1"/30.7 cm capacitive touch screen.
- Bandwidth up to 1.5 GHz, 5 GS/s sampling, 1 million wfms/s update rate, MSO.
Keysight InfiniiVision MSOX4000G "All Inclusive" MS Oscilloscopes up to 1.5 GHz, 5 GS/s
Models Keysight MSOX4022G, MSOX4024G, MSOX4032G, MSOX4034G, MSOX4052G, MSOX4054G, MSOX4104G, MSOX4154G
Keysight is adding a "4000G" family to the 4000 X-series. The "G series" is characterized in particular by the fact that many important options are already included here as standard (see comparison table below). This helps you save money, time and effort. The other specifications of the 4000G series are as high quality as you are used to from Keysight oscilloscopes. Special highlights include the large 12.1"/30.7 cm touch screen, the sophisticated zone triggers and the high signal acquisition rate of 1 million Wfms/s.
- High quality MegaZoom IV digital storage/mixed-signal oscilloscopes.
- 2 or 4 analog channels.
- 16 digital/logic analysis channels (MSO/mixed signal models).
- Bandwidth 200, 350, 500 MHz, 1 or 1.5 GHz.
- Max. Sampling rate 5 GS/s.
- Max. memory depth 4 Mpts; segmented memory as standard.
- Max. Signal update rate >1,000,000 Wfms/s.
- Zone touch trigger as standard.
- Advanced FFT as standard.
- Multi-domain analysis: Gated FFT.
- Advanced math: Standard, display of one function.
- Integrated digital voltmeter/DVM as standard.
- Integrated hardware counter standard: 5-digit frequency or period counter (8-digit with external 10 MHz clock reference).
- Also included as standard on the 4000G X-Series:
- Integrated 2-channel signal generator.
- Signal and measurement histograms.
- Mask limit test, measurement limit test.
- Frequency response analysis (Bode plot).
- Serial trigger and decoding for I2C, SPI, UART, I2S and USB PD (others optional).
- Advanced HDTV video analysis.
- 12.1"/30.7 cm capacitive touch display.
- Interfaces: USB 2.0 Host & Device (USB mouse and keyboard support), Ethernet/LAN/LXI, SVGA video output; optional GPIB.
Model Overview
Model | MSOX4022G MSOX4024G | MSOX4032G MSOX4034G | MSOX4052G MSOX4054G | MSOX4104G | MSOX4154A |
Analog channels | 2 | 4 | 2 | 4 | 2 | 4 | 4 | 4 |
Bandwidth | 200 MHz | 350 MHz | 500 MHz | 1 GHz | 1.5 GHz |
Sample rate | 5 GS/s half channel, 2.5 GS/s all channels | ||||
Signal update rate | >1 million Wfms/s | ||||
Memory depth | Standard 4 Mpts, segmented memory | ||||
MegaZoom | Yes | ||||
Logic analysis (mixed signal) | 16 digital channels | ||||
Signal generator | Standard: 2 channels, sine (20 MHz), square/pulse (20 MHz), ramp/triangle (200 kHz), pulse (10 MHz/min. pulse width 20 ns), noise (typ. 20 MHz), sinc (1 MHz), exponential rise/fall (5 MHz), cardiac (200 kHz), Gaussian pulse (5 MHz), arbitrary signal: 1...8192 points, 10 bit resolution, sampling rate 100 MS/s, filter bandwidth 10 MHz; modulation: AM, FM, FSK, FSK | ||||
Voltmeter | Standard: ACeff, DC, DCeff, frequency; resolution ACV/DCV: 3 digits, frequency: 5.5 digits, measuring rate 100 times per s; autoranging | ||||
Counter | 5-digit frequency or period counter (8-digit with external 10 MHz clock reference) | ||||
Trigger and decoding | I2C, SPI, UART, I2S and USB PD as standard, others otional | ||||
Other standard functions | Zone trigger, signal and measurement histograms, mask and measurement limit test, frequency response/bode analysis, advanced HDTV video analysis | ||||
Display | 12.1"/30.7 cm high resolution capacitive touch display | ||||
Interfaces | USB 2.0 host (3x) & device, USB test and measurement class (USBTMC) compatible; 10/100Base-T Ethernet/LAN, LXI IPv6 enhanced function, web remote control, VNC web interface (via popular web browsers); SVGA on rear panel; optional GPIB port (N4865A GPIB-to-LAN adapter) |
Included: Keysight MSOX 4024 G, 4034 G, 4054 G, 4104 G, or 4254 G, calibration certificate (recommended calibration interval 2 years), 1 probe per channel (N2894A 700 MHz passive probe, 10:1 attenuation), N2756A 16-digital channel/MSO cable (1 per oscilloscope included with all MSO models and with DSOXPERFMSO upgrade), localized front panel labeling, interface and built-in help system, power cord, front panel protective cover, CD with user manual, service manual, and programming manual.
Comparison A and G Series
Model | InfiniiVision 4000A X-series | InfiniiVision 4000G X-series |
Bandwidth | 200 MHz to 1.5 GHz | 200 MHz to 1.5 GHz |
Sample rate | 5 GS/s | 5 GS/s |
Signal acquisition rate | 1,000,000 Wfms/s | 1,000,000 Wfms/s |
Channels | 2 or 4, MSO +16 digital/logic | 2 or 4, MSO +16 digital/logic |
Zone trigger | Standard | Standard |
Display | 12.1"/30.7 cm touchscreen | 12.1"/30.7 cm touchscreen |
Segmented memory | Standard | Standard |
Signal and measurement histograms | - | Standard |
2-channel signal generator | Optional | Standard |
Trigger and decoding | Optional | Standard I2C, SPI, UART, I2S and USB PD, other otional |
Mask and measurement limit test | Optional | Standard |
Frequency response/bode analysis | Optional | Standard |
Advanced HDTV video analysis | Optional | Standard |
Frequently Asked Questions:
Question: What do DSOX/MSOX 4000G and 4000G have in common?
Answer: The proven features of the 4000A X series have been adopted to the series G, including, for example
- the high-quality design with excellent basic specifications,
- the 12.1"/30.7 cm high-resolution capacitive touchscreen,
- the sophisticated hardware triggers, such as zone triggers,
- the segmented memory,
- the multi-functionality with voltmeter, counter, signal generator, serial bus decoding etc.
The device series are therefore compatible and the operation and programming are identical. The 4000G X series therefore also fits perfectly into the usability philosophy of the InfiniiVision series: consistent operation from the smallest to the largest model. Once you have learned how to operate one model, you can quickly and easily switch to another from the InfiniiVision series.
Question: What is the difference between DSOX/MSOX 4000G and 4000A?
Answer: In addition to the housing color, functions that were optional in the A series are now standard (see table above):
- Integrated 2-channel signal generator, 20 MHz.
- Mask limit test, measurement limit test.
- Frequency response analysis (Bode plot).
- Serial trigger and decoding for I2C, SPI, UART, I2S and USB PD (others optional).
- Extended HDTV video analysis.
Signal and measurement histograms, which are not possible with the A series, have been added.
Question: What interfaces does the 4000G X-Series offer?
Answer: The proven interfaces have also been adopted from the A series: USB 2.0 host (3x) & device, USB test and measurement class (USBTMC) compatible; 10/100Base-T Ethernet/LAN, LXI IPv6 extended function, web remote control, VNC web interface (via common web browsers). Optionally, an ▸N4865A/ICS model 4865B can be used for GPIB systems (adapter from LAN to GPIB/IEEE488).
Agilent's Electronic Measurement Group is now Keysight Technologies.
Information on product safety:
Manufacturer:
Keysight, 1400 Fountaingrove Parkway, Santa Rosa, CA/USA
www.keysight.com
(Keysight Technologies Deutschland GmbH)
Related Products