HIOKI PQ3100/PQ3198 Portable Power Quality Analyzers

starting 3.924,62
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Benefits of the PQ3100/PQ3198 Portable Analyzers and Recorders for Power Quality

  • Investigate power characteristics, analyze causes of problems in power supply.
  • Record voltage, current, power, harmonics, and flicker simultaneously along a single time axis.
  • Measure up to 6000 AAC.

HIOKI PQ3100/PQ3198 Portable Power Quality Analyzers

The HIOKI PQ3100 and PQ3198 are portable power quality analyzers available as main unit only or bundled with current clamps. The devices are used to investigate power characteristics and analyze the causes of problems in power supply. The PQ3100 and PQ3198 offer 3-phase 4-wire power quality analysis compliant to IEC61000-4-30 Class S standards and on-screen guide for easy setup and testing.

  • HIOKI PQ3100:
    • Record voltage, current, power, harmonics, and flicker simultaneously along a single time axis.
    • Measure up to 6000 AAC.
    • Capture all power anomalies such as instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data.
    • Quick Set: Easy-to-understand on-screen guide for measurement procedures.
    • Bundled PQ ONE application software makes it easy to create reports.
    • Record waveforms for up to 1 s before and 10 s after an anomaly occurs.
    • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor).
    • Directly supply power to connected current sensors.
    • Send measured values to HIOKI data loggers using a Bluetooth wireless technology compatible adaptor (LR8410 Link-compatible products), Ver. 2.0 and later.
  • HIOKI PQ3198:
    • Verify power problems in accordance with the IEC61000-4-30 edition 3 Class A standard.
    • High accuracy and continuous gapless recording (V: ±0.1% of nominal voltage, A: ±0.1% rdg. ±0.1% f.s., W: ±0.2% rdg. ±0.1% f.s.).
    • Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz.
    • Maximum 6000 Vpeak transient voltage up to 700 kHz.
    • Measure up to 6000 AAC.
    • Two systems of power measurement and efficiency calculation for (channel 1, channel 2, channel 3) and channel 4.
    • Make simple measurements of inverters with 40 to 70 Hz fundamental frequency and max. 20 kHz carrier frequency.
    • Easily create reports with bundled PQ ONE application software .
    • Optional GPS BOX for synchronizing multiple devices.

Model Overview

ModelHIOKI PQ3100HIOKI PQ3198
Measurement line typeSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire plus one extra input channel
Number of channels4 voltage, 4 current
Fundamental frequencyDC/50 Hz/60 HzDC/50 Hz/60 Hz/400 Hz
RangesVoltage: Voltage measurement 1000.0 VRMS or DC, transient measurement 2.200 kVpeak;
current: 50.000 mAAC...5.0000 kAAC, 10.000 ADC...2.0000 kADC (depends on current sensor in use);
power: 50.000 W...6.0000 MW (determined automatically based on current range in use)
Voltage: Voltage measurement 600.00 VRMS, transient measurement 6.0000 kVpeak;
current: 500.00 mAAC...5.0000 kAAC (depends on current sensor in use);
power: 300.00 W...3.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracyVoltage: ±0.2% of nominal voltage,
current: ±0.1% rdg. ±0.1% f.s. + current sensor accuracy,
active power: DC ±0.5% rdg. ±0.5% f.s. + current sensor accuracy,
AC±0.2% rdg. ±0.1% f.s. + current sensor accuracy
Voltage: ±0.1% of nominal voltage,
current: ±0.1% rdg. ±0.1% f.s. + current sensor accuracy,
active power: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy
Measurement items
  1. Transient over voltage: 200 kHz sampling.
  2. Frequency cycle: Calculated as one cycle.
  3. Voltage (1/2) RMS, current (1/2) RMS: one cycle calculation refreshed every half cycle.
  4. Voltage swell, voltage dips, voltage interruption, RVC (ver. 2.0 or later): Voltage (1/2) RMS calculation.
  5. Inrush current: Half-cycle calculation: Calculated as the current RMS value for current waveform data sampled every half-cycle.
  6. Frequency 200 ms: Calculated as 10 or 12 cycles.
  7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period.
  8. Voltage waveform peak, current waveform peak.
  9. Voltage, current, active power, apparent power, reactive power, active energy, apparent energy, reactive energy, energy cost, power factor, displacement power factor, voltage unbalance factor, vurrent unbalance factor.
  10. Voltage crest factor, current crest factor.
  11. Harmonic/harmonic phase angle (voltage/current), harmonic power: 0th to 50th orders.
  12. Harmonic voltage-current phase angle: 1th to 50th orders.
  13. Total harmonic distortion factor (voltage/current).
  14. Inter harmonic (voltage/current): 0.5th to 49.5th orders.
  15. K factor (multiplication factor).
  16. IEC flicker, ΔV10 flicker.
  1. Transient voltage: 2 MHz sampling.
  2. Frequency cycle: Calculated as one cycle, 40 to 70 Hz.
  3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle; current (1/2) RMS: half-cycle calculation.
  4. Voltage swell, voltage dips, voltage interruption.
  5. Inrush current.
  6. Voltage waveform comparison.
  7. Instantaneous flicker value: As per IEC61000-4-15.
  8. 200 ms frequency: Calculated as 10 or 12 cycles, 40 to 70 Hz.
  9. 10 s frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz.
  10. Voltage waveform peak, current waveform peak.
  11. Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance factor, current unbalance factor, and efficiency.
  12. High-order harmonic component (voltage/current): 2 kHz to 80 kHz.
  13. Harmonic/ Harmonic phase angle (voltage/current), harmonic power: 0th to 50th orders.
  14. Harmonic voltage-current phase angle: 1th to 50th orders.
  15. Total harmonic distortion factor (voltage/current).
  16. Inter harmonic (voltage/current): 0.5th to 49.5th order.
  17. K factor (multiplication factor).
  18. IEC flicker, ΔV10 flicker.
RecordMax. recording interval 1 year, max. number of recordable events: 9999 x 365 daysRepeated ON: 1 year, max. recording event: 9999 x 366 days (up to 9999 events per day);
repeated OFF: 35 days, max. recording event: 9999 events
InterfacesSD/SDHC memory card, RS232C (for communication/LR8410 link), LAN (HTTP server/FTP/send e-mail), USB 2.0 (for communication); logger connectivity: Sends measured values wirelessly to logger by using a Bluetooth wireless technology serial conversion adaptor (supported devices: Hioki LR8410 Link-compatible loggers), Ver. 2.0 and laterSD/SDHC memory card, LAN (HTTP server function/FTP function), USB2.0 (for communication)
Display6.5"/16.5 cm TFT color LCD (640x480 dots)
Power supplyAC adaptor Z1002, battery pack Z1003
Dimensions (mm)300 x 211 x 68; 2.5 kg (including battery pack)

Included: HIOKI power quality analyzer PQ 3100 or PQ 3198, instruction manual, measurement guide, voltage cord L1000-05 set (red/yellow/blue/gray/black, alligator clips, spiral tubes), color clip set (for identifying clamp sensor color), spiral tubes, AC adaptor Z1002, strap, USB cable (1 m), battery pack Z1003, PQ ONE (software, CD).

Model Versions

VersionDescription
PQ3100Power quality analyzer, main unit only without current sensors
PQ3100-91Power quality analyzer kit, contains PQ3100 main unit, 2x AC current sensor CT7136 (600 A), SD memory card 2GB Z4001, carrying case C1009
PQ3100-92Power quality analyzer kit, contains PQ3100 main unit, 4x AC current sensor CT7136 (600 A), SD memory card 2GB Z4001, carrying case C1009
PQ3100-94Power quality analyzer kit, contains PQ3100 main unit, 4x AC flexible current sensor CT7045 (6000 A), SD memory card 2GB Z4001, carrying case C1009
PQ3198Power quality analyzer, main unit only ithout current sensors
PQ3198-92Power quality analyzer kit, contains main unit, 4x AC current sensor CT7136 (600 A), 3x patch cord L1021-02, carrying case C1009
PQ3198-94Power quality analyzer kit, contains main unit, 4x AC current sensor CT7045 (6000 A), 3x patch cord L1021-02, carrying case C1009