HIOKI IM35xx Series LCR Meters and Impedance Meters
starting €
2.877,42
including VAT
free shipping (Germany)
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads
Benefits of the IM35xx Series LCR Meters for R&D and Industrial Production Lines
- High accuracy LCR testing, model with transformer measurement mode.
- Fast measuring speed up to 1 ms or 2 ms.
- Exceptional specifications and cost-performance for a wide range of applications.
HIOKI IM35xx Series LCR Meters and Impedance Meters
HIOKI IM3523/IM3523A, IM3533, IM3536 Industrial LCR Meters
The HIOKI IM35xx is a series of high accuracy and reliability LCR and impedance meters for professional industrial production lines and R&D applications in the testing of electronic components.
- IM3523(A) basic LCR meter:
- |Z|, L, C, R testing; testing source frequency 40 Hz...200 kHz.
- Fast measuring time 2 ms.
- ±0.05% accuracy with wide measurement range (DC, 40 Hz...200 kHz, 5 mV...5 V, 10 µA...50 mA).
- Built-in comparator and BIN functions.
- Non-stop testing over mixed measurement conditions such as C-D (120 Hz) and ESR (100 kHz).
- IM3533(-01) enhanced LCR meter:
- |Z|, L, C, R testing; testing source frequency 1 mHz...200 kHz.
- Fast measuring time 2 ms.
- Transformer measurement mode: Turn ratio, mutual inductance and inductance difference measurements of transformers and coils.
- IM3533-01: Frequency sweep measurement.
- Internal DC bias to facilitate HDMI compliance testing.
- ±0.05% accuracy with wide measurement range (DC, 1 mHz...200 kHz, 5 mV...5 V, 10 µA...50 mA).
- Non-stop testing over mixed measurement conditions such as C-D and ESR.
- Built-in low impedance high precision mode effective for testing low inductance or the ESR of aluminum electrolysis capacitance.
- 2 m/4 m cable setting in addition to the standard 0 m/1 m.
- Touch screen with intuitive operation.
- IM3536 general-purpose LCR meter:
- |Z|, L, C, R testing, testing source frequency DC, or 4 Hz...8 MHz (customizable up to 10 MHz on request).
- Fast measuring time 1 ms.
- Accuracy guaranteed range from 1 mΩ, low-impedance measurement with unmatched repeatability.
- High-precision measurement of ±0.05% rdg. (representative value).
- DC bias function: Measure under conditions simulating actual use or in accordance with industry standards.
Model Overview
Model | HIOKI IM3523(A) | HIOKI IM3533(-01) | HIOKI IM3536 |
Measurement modes | LCR (measurement with single condition), continuous testing (continuous measurement under saved conditions) | LCR (measurement with single condition), transformer testing (N, M, ΔL) IM3533: Continuous testing (continuous measurement under saved conditions, LCR mode) IM3533-01: Analyzer (sweep testing), continuous cesting (LCR/analyzer mode) | LCR (measurement with single condition), continuous testing (continuous measurement under saved conditions) |
Measurement parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tan δ), σ, ε | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tan δ), N, M, ΔL, T | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tan δ), σ, ε |
Measurement range | 100 mΩ...100 MΩ, 10 ranges (all parameters defined in terms of Z) | ||
Displayable range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp: ±(0.00000 [unit]...9.99999 G [unit]) real value display for Z and Y only; θ: ±(0.000°...180.000°); D: ± (0.00000...9.99999); Q: ±(0.00...99999.9); Δ%: ±(0.0000%...999.999%) | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp: ±(0.00000 [unit]...9.99999 G [unit]) real value display for Z and Y only; θ: ±(0.000°...180.000°); D: ±(0.00000 to 9.99999); Q: ±(0.00...99999.9); Δ%: ±(0.0000%...999.999%); T: -10.0...99.9°C | Z: 0.00 mΩ...9.99999 GΩ; Y: 0.000 nS...9.99999 GS; &theta: ±(0.000°...180.000°); Q: ±(0.00...9999.99); Rdc: ±(0.00 mΩ...9.99999 GΩ); D: ±(0.00000...9.99999); Δ%: ±(0.000% to 999.999%), or other |
Basic accuracy | Z: ±0.05% rdg. θ: ±0.03° | Z: ±0.05% rdg. θ: ±0.03° | Z ±0.05% rdg. θ: ±0.03°(representative value, measurable range 1 mΩ...200 MΩ) |
Measurement frequency | 40 Hz...200 kHz (5 digits setting resolution) | 1 mHz...200 kHz (5 digits setting resolution, minimum resolution 1 mHz) | 4 Hz...8 MHz (5 digits setting resolution, minimum resolution 10 mHz) |
Measurement signal level | Normal mode V mode, CV mode: 5 mV...5 VRMS, 1 mVRMS steps; CC mode: 10 µA...50 mARMS, 10 µARMS steps | Normal mode V mode, CV mode: 5 mV...5 VRMS, 1 mVRMS steps; CC mode: 10 µA...50 mARMS, 10 µARMS steps. Low impedance high accuracy mode V mode, CV mode: 5 mV...2.5 VRMS, 1 mVRMS steps; CC mode: 10 µA...100 mARMS, 10 µARMS steps | Normal mode; V mode/CV mode 4 Hz...1.0000 MHz: 10 mV...5 VRMS (maximum 50 mARMS), 1.0001 MHz...8 MHz: 10 mV...1 VRMS (max. 10 mARMS). Low impedance high accuracy mode V mode/CV mode 4 Hz...1.0000 MHz: 10 mV...1 VRMS (max.m 100 mARMS). Normal mode CC mode 4 Hz...1.0000 MHz: 10 µA...50 mARMS (max. 5 VRMS), 1.0001 MHz...8 MHz: 10 µA...10 mARMS (max. 1 VRMS). Low impedance high accuracy mode CC mode 4 Hz...1.0000 MHz: 10 µA...100 mARMS (max. 1 VRMS). DC resistance measurement measurement signal level: Fixed at 1 V. DC bias measurement generating range: DC voltage 0...2.50 V (10 mV resolution); in low Z high accuracy mode: 0...1 V (10 mV resolution) |
Output impedance | 100 Ω | Normal mode: 100 Ω, low impedance high accuracy mode: 25 Ω | Normal mode: 100 Ω, low impedance high accuracy mode: 10 Ω |
Display | Monochrome LCD | 5.7"/14.5 cm touch-screen color TFT, display can be set to ON/OFF | |
Measurement time | 2 ms (1 kHz, FAST, representative value) | 2 ms (1 kHz, FAST, display OFF, representative value) | 1 ms (fastest time) |
Functions | Comparator, BIN measurement (classify function), panel loading/saving, memory function | ||
- | DC bias measurement, DC resistance temperature compensation (converted reference temperature display) | Trigger function, open/short compensation, contact check | |
Interfaces | EXT I/O (handler), USB; optional: Choose 1 from RS232C, GPIB, or LAN. Version A: EXT I/O (handler), USB, LAN (options for RS232C or GPIB not available) | EXT I/O (handler), USB, USB flash drive; optional: Choose 1 from RS232C, GPIB, or LAN | EXT I/O (handler), USB, USB flash drive LAN, GPIB, RS232C, BCD |
Dimensions (mm) | 260 x 88 x 203; 2.4 kg | 330 x 119 x 168; 3.1 kg | 330 x 119 x 230; 4.2 kg |
Included: LCR meter HIOKI IM 3523, 3533, or 3536, power cord, instruction manual, CD with software, user manual.