dydaqlog DL-160-16-D - IIoT Datalogger with WLAN and Ethernet/LAN
Benefits of the dydaqlog Sensor Datalogger, Monitoring and Automation System
- Datalogger for highprecision data acquisition with flexible sensor inputs (U, I, TC, PT50/100/500/1000, strain gauge)
- Configure and control measurement, display data with web interface.
- Store data in internal Flash memory, send to a Cloud or a server.
dydaqlog DL-160-16-D IIoT WLAN and Ethernet/LAN Datalogger
The dydaqlog IIoT datalogger DL-160-16-D (article code DL-V-002-A1) combines the benefits of flexible sensor inputs and precise data acquisition with an intuitive operation and seamless connectivcity to industrial Cloud solutions. Measurement data is accessible at any time and from anywhere in the Industrial Internet of Things. The datalogger has 16 differential analog inputs with 24 bit resolution. The inputs can be used for current and voltage acquisition or for the direct connection of thermocouples, PT50/100/500/1000 resistance thermometers and and strain gauges. At the same time the dydaqlog datalogger is a versatile webserver. All functions are configured and managed using a modern web interface in a browser. Measurement data can be displayed online or offline. As communication interface the datalogger uses WLAN or Ethernet/LAN. The MQTT protocol is supported for data transmission into a Cloud.
- 16 differential analog inputs with 24 bit resolution and a sample rate of max. 20 Hz per channel.
- Input: Voltage, current, thermocouple (J, K, T, E, R, S, B, N), PT100/1000, resistors, resistive bridge trasnduvers (6-wire).
- Input voltage ranges: ±10 V, ±5 V, ±3 V, ±1.6 V, ±800 mV, ±400 mV, ±200 mV, ±100 mV. Input current ranges: 0...20 mA.
- Digital inputs: 6, opto-coupled.
- Digital outputs: 6, electronic relays.
- Processor: Quadcore 1.4 GHz ARM Cortex-A53 with integrated webserver.
- Data storage: MicroSD Card internal, 1 GSamples.
- Power supply: 10...36 VDC (external power supply adaptor incl.).
- Host interfaces: WLAN, Ethernet/LAN.
- Configuration interface: WLAN hotspot. Web interace for configuration and measurement data display.
- Access to industrial Cloud solutions with MQTT protocol.
- Alarms can trigger actions like switching of digital outputs, sending e-mails or short messages.
- Rugged Aluminum enclosure, full IP65 protection.
Model Overview
Model | dydaqlog DL-160-16-D | |
Analog inputs | Number | 16 differential; all analog inputs can be configured individually |
A/D converter | Sigma-Delta; resolution 24 bit; sample rate (max.) per channel 20 Hz | |
Ranges | Voltage: ±10 V, ±5 V, ±3 V, ±1.6 V, ±800 mV, ±400 mV, ±200 mV, ±100 mV, Current: 0...20 mA, Input resistance 1 MΩ | |
Coupling | DC | |
Sensor connection | Thermocouples type B, E, J, K, N, R, S, T, PT50, PT100, PT500, PT1000, resistive bridge transducer, eg. strain gauges. Connection of external sensors and I/O-modules via MQTT or Modbus | |
Digital inputs | Number | 6, opto-coupled |
Level | TTL, Low: <0.8 V, High: >2.4 V (max.) | |
Digital outputs | Number | 6 electronic relays |
Switching voltage | 40 V max. at 1 A | |
Counter inputs | Channels | 6 (alternative usage of digital inputs) |
Input frequency | max. 1 kHz | |
Processor | ARM Cortex A-53 quad core 1.4 GHz mikroprozessor with integrated webserver; web interface for configuration and data display | |
Data storage | MicroSD Card internal; for 1 GSamples of measurement data | |
Other features | The measurement channels can be calculated online or monitored for threshold values/limits. Alarms can trigger actions like switching of digital outputs or sending e-mails | |
Host interface | WLAN (antenna incl.) 802.11 b/g/n/ac (2.4 and 5 GHz, LAN/Ethernet 1x Gigabit RJ45), for configuration and data transmission; access to industrial Cloud solutions with MQTT protocol. Measurement data can be stored in internal memory, transmitted to a server or a data Cloud. Option, on request: Cellular Radio 4G/LTE - configuration and operation via web interface, transmission of messages, e-mails, data transmission via MQTT, FTP | |
Power supply | 10...36 VDC (external power supply adaptor incl.) | |
Operating temperature | 0...+50°C | |
Enclosure | Aluminum, full IP65 protection; available as optional accessories: Transportation cases, holding clamp for DIN-rail | |
Dimesions (mm) | 211 x 70 x 209, 1.7 kg |
Included: Datalogger dydaqlog (DL-160-16-D/DL-V-004-A1), WLAN antenna, external power supply adaptor.
Optional accessories: DIN-rail mountable holding clamp, transportation case.