Dx000PWRBKeysight InfiniiVision Power Applications Software Package
Dx000PWRB Keysight InfiniiVision Power Applications Software Package
The Keysight InfiniiVision series oscilloscope/MSO software-oriented options are available via online licensing. These software-oriented options (such as serial decoding of different buses, mask limit test, power analysis, FRA/Bode) have been bundled into application-specific packages. The packages can be registered and used according to a perpetual license. Other hardware-oriented upgrades such as signal generator, memory, bandwidths and mixed signal upgrades are available as before. The InfiniiVision 1000X series is excluded from this licencing system. The bundles PWRB replace the former bundles PWRA.
The power applications bundle includes (depending on scope model):
- Input AC power quality.
- Current harmonics analysis.
- Switching device analysis.
- RDS(ON) and VCE(SAT) analysis.
- Modulation analysis.
- Output ripple analysis.
- Turn on/off time analysis.
- Transient response analysis.
- PSRR (power supply rejection ratio).
- Control loop response analysis.
Model Overview Dx000PWRB
Scope model | InfiniiVision 3000A series | InfiniiVision 3000T series | InfiniiVision 4000A series | InfiniiVision 6000A series | ||
Bundle version | D3000PWRB | D3000PWRB | D4000PWRB | D6000PWRB | ||
Power supply characterization measurements | Input analysis | Real power | ✓ | ✓ | ✓ | ✓ |
Apparent power | ✓ | ✓ | ✓ | ✓ | ||
Reactive power | ✓ | ✓ | ✓ | ✓ | ||
Power factor | ✓ | ✓ | ✓ | ✓ | ||
Crest factor (voltage and current) | ✓ | ✓ | ✓ | ✓ | ||
Phase angle | ✓ | ✓ | ✓ | ✓ | ||
Current harmonics | ✓ | ✓ | ✓ | ✓ | ||
Inrush current | ✓ | ✓ | ✓ | ✓ | ||
Switching device analysis | Switching loss | ✓ | ✓ | ✓ | ✓ | |
RDS(ON) | ✓ | ✓ | ✓ | ✓ | ||
VCE(SAT) | ✓ | ✓ | ✓ | ✓ | ||
Slew rate (voltage and current) | ✓ | ✓ | ✓ | ✓ | ||
Modulation analysis | ✓ | ✓ | ✓ | ✓ | ||
Auto probe deskew | ✓ | ✓ | ✓ | ✓ | ||
Output analysis | Output ripple | ✓ | ✓ | ✓ | ✓ | |
Turn on/off time | ✓ | ✓ | ✓ | ✓ | ||
Efficiency | ✓ | ✓ | ✓ | ✓ | ||
Transient response | ✓ | ✓ | ✓ | ✓ | ||
Frequency response analysis | PSRR | - | ✓ | ✓ | ✓ | |
Control loop response | - | ✓ | ✓ | ✓ | ||
Other advanced analysis capabilities | Frequency response analysis (Bode plots) | - | ✓ | ✓ | ✓ | |
USB-PD (power delivery) trigger and decode | - | ✓ | ✓ | ✓ | ||
Mask test | ✓ | ✓ | ✓ | ✓ | ||
Advanced math | ✓ | standard | standard | standard |
Pick the Right Probe for Your Keysight Oscilloscope
Applications | Speed and signal types | Recommended probe | Required probe bandwidth |
LIN | 625 kbps, single-ended | Passive probes (1 MΩ, single-ended) | >50 MHz |
ARINC 425 | 100 kbps, differential | ▸N2791A/▸N2818A | 200 MHz |
CAN 2.0 | 5 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
CAN FD | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
MIL Std 1553 | 1 Mbps, differential, ±25 VPP | ▸N2791A/▸N2818A | 200 MHz |
I²S (audio) | approx. 2.8 MHz, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
I²C/SMbux | <4 MHz, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
RS232/UART | <10 Mbps, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
RS422/485 | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
FlexRay | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
SPI | 1...100 MHz, single-ended | Passive probes (1 MΩ, single-ended) or ▸N2795A | >100 MHz passive or 1 GHz active |
MOST | 150 Mbps, differential | N2750A | 1.5 GHz |
USB 2.0 | 480 Mbps, differential | N2750A | 1.5 GHz |
USB power delivery | 300 kbps, single-ended | Passive probes (1 MΩ, single-ended) | >50 MHz |
Related Products