Yokogawa CL Series Clamp-On Testers
starting €
225,80
including VAT
plus shipping
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads
Benefits of the Yokogawa CL Series Handheld Devices in Clampmeter Design
- Combination of current clamp and measurement instrument with display.
- Measurement of AC current, AC/DC current, and leakage current.
- Wide clamp opening for conductors up to 54 mm in diameter.
Yokogawa CL Series Clamp-On Testers
Yokogawa CL series are handy, light weight and compact clamp-on testers. Models are available for AC current measurement, AC/DC current measurement and leakage current measurements, with various current ranges and diameters. Depending on the model they have a mean value or true RMS display. All models have a data old function.
Yokogawa CL Models for AC Current
Model | CL120 | CL130 | CL135 | CL150 | CL155 | |
Diameter of measurable conductor | 24 mm | 30 mm | 30 mm | 54 mm | 54 mm | |
Display | 1999 | 1999 | 1999 | 3999 | 3999 | |
DC current | Range | - | - | - | - | - |
Resolution | - | - | - | - | - | |
AC current | Range | 20/200 A | 200/600 A | 200/600 A | 400/2000 A | 400/2000 A |
Resolution | 0.01 A | 0.1 A | 0.1 A | 0.1 A | 0.1 A | |
Frequency characteristics | 40 Hz...1 kHz | 40 Hz...1 kHz | 40 Hz...1 kHz | 40 Hz...1 kHz | 40 Hz...1 kHz | |
Method of detection | Mean value | Mean value | True RMS | Mean value | True RMS | |
Other measurement | AC voltage | - | ✓ | ✓ | ✓ | ✓ |
DC voltage | - | - | - | ✓ | ✓ | |
Continuity check | - | ✓ | ✓ | ✓ | ✓ | |
Frequency | - | - | - | - | - | |
Temperature | - | - | - | - | - | |
Other functions | Recorder output | - | - | - | ✓ | ✓ |
Waveform monitor output | - | - | - | - | - | |
Data hold | ✓ | ✓ | ✓ | ✓ | ✓ | |
Auto hold | - | - | - | - | - | |
Peak hold | - | - | - | ✓ | ✓ | |
Maximum value memory | - | - | - | - | - | |
Mean value display | - | - | - | - | - | |
Filter | - | - | - | - | - | |
Range hold (current range) | ✓ | ✓ | ✓ | ✓ (current range) | ✓ (current range) | |
Auto ZERO adjust | - | - | - | - | - | |
Auto power-off | ✓ | - | - | ✓ (sleep function/power-down) | ✓ (sleep function/power-down) | |
Safety standards | EN61010-1, EN61010-2-032 (CAT III 300 V) |
EN61010-1, EN61010-2-031, EN61010-2-032 (CAT III 600 V) |
EN61010-1, EN61010-2-031, EN61010-2-032 (CAT III 600 V) |
EN61010-1, EN61010-2-031, EN61010-2-032 (CAT M 600 V, CAT II 1000 V) |
EN61010-1, EN61010-2-031, EN61010-2-032 (CAT HI 600 V, CAT II 1000 V) |
Yokogawa CL Models for AC/DC Currents
Model | CL220 | CL235 | Cl250 | CL255 | |
Diameter of measurable conductor | 24 mm | 33 mm | 55 mm | 55 mm | |
Display | 3999 | 3999 | 3999 | 3999 | |
DC current | Range | 40/300 A | 400/1000 A | 400/2000 A | 400/2000 A |
Resolution | 0.01 A | 0.1 A | 0.1 A | 0.1 A | |
AC current | Range | 40/300 A | 400/600 A | 400/2000 A | 400/2000 A |
Resolution | 0.01 A | 0.1 A | 0.1 A | 0.1 A | |
Frequency characteristics | 20 Hz...1 kHz | 40 Hz...1 kHz | 40 Hz...1 kHz | 30 Hz...1 kHz | |
Method of detection | Mean value | True RMS | Mean value | True RMS | |
Other measurement | AC voltage | - | ✓ | ✓ | ✓ |
DC voltage | - | ✓ | ✓ | ✓ | |
Continuity check | - | ✓ | ✓ | ✓ | |
Frequency | - | ✓ | - | ✓ | |
Temperature | - | - | - | - | |
Other functions | Recorder output | - | - | ✓ | ✓ |
Waveform monitor output | - | - | - | - | |
Data hold | ✓ | ✓ | ✓ | ✓ | |
Auto hold | - | - | - | - | |
Peak hold | - | ✓ | - | ✓ | |
Maximum value memory | - | - | ✓ | - | |
Mean value display | - | ✓ | - | ✓ | |
Filter | - | - | - | - | |
Range hold (current range) | - | - | ✓ (current range) | - | |
Auto ZERO adjust | ✓ | ✓ | ✓ | ✓ | |
Auto power-off | ✓ (sleep function/power-down) | ✓ (sleep function/power-down) | ✓ (sleep function/power-down) | ✓ (sleep function/power-down) | |
Safety standards | EN61010-1, EN61010-2-032 (CAT III 300 V) | EN61010-1,EN61010-2-031, EN61010-2-032 (CAT III 600 V) | EN61010-1, EN61010-2-031, EN61010-2-032 (CAT III 600 V, CAT II 1000 V) | EN61010-1,EN61010-2-031, EN61010-2-032 (CAT III 600 V, CAT II 1000 V) |
Yokogawa CL Models for Leakage Current
Model | CL320 | CL340 | CL345 | CL360 | ||
Diameter of measurable conductor | 24 mm | 40 mm | 40 mm | 68 mm | ||
Display | 1999 | 3999 | 4200 | 1999 | ||
DC current | Range | - | - | - | - | |
Resolution | - | - | - | - | ||
AC current | Range | 20/200 mA, 200 A | 40/400 mA, 400 A | 40/400 mA, 400 A | 200 mA/2/20/200/1000 A | |
Resolution | 0.01 mA | 0.01 mA | 0.01 mA | 0.1 mA | ||
Frequency characteristics | 40...400 Hz | 20 Hz...1 kHz | 20 Hz...1 kHz | 40 Hz...1 kHz | ||
Method of detection | Mean value | Mean value | True RMS | Mean value | ||
Other measurement | AC voltage | - | - | - | - | |
DC voltage | - | - | - | - | ||
Continuity check | - | - | - | - | ||
Frequency | - | - | - | - | ||
Temperature | - | - | - | - | ||
Other functions | Recorder output | - | - | - | ✓ | |
Waveform monitor output | - | - | - | ✓ | ||
Data hold | ✓ | ✓ | ✓ | ✓ | ||
Auto hold | - | - | - | - | ||
Peak hold | - | ✓ | ✓ | ✓ | ||
Maximum value memory | - | - | - | - | ||
Mean value display | - | - | - | - | ||
Filter | ✓ | ✓ | ✓ | ✓ | ||
Range hold (current range) | ✓ | ✓ | ✓ | ✓ | ||
Auto ZERO adjust | - | - | - | - | ||
Auto power-off | ✓ | ✓ | ✓ | - | ||
Safety standards | EN61010-1, EN61010-2-032 (CAT III 300 V) | EN61010-1, EN61010-2-032 (CAT III 300 V) | EN61010-2-032 (CAT III 300 V) | EN 61010-1, EN 61010-2-032 (CAT III 300 V) |
Yokogawa CL Process Meter
Model | CL420 | |||||
Diameter of measurable conductor | max. 6 mm | |||||
DC current | Range and resolution [measuring range]: 20.00 mA [0.00
to ±21.49 mA], 100.0 mA [±21.0 to ±126.0 mA] Measuring accuracy: ±(0.2% rdg + 5 dgt), ±(1.0% rdg + 5 dgt) |
|||||
DC voltage OUTPUT | 20.00 mA [0.0 to ±214.9 mV], 100.0 mA
[±210 to ±1260 mV] (DCA accuracy) + (±0.5 mV), (DCA accuracy) + (±3 mV) |
|||||
Display | 4-digit LCD numeric display | |||||
Response time | Approx. 1.5 s (2.5 s when across the range) | |||||
Range switching | Auto range | |||||
Operating temperature and humidity | -10...+50°C, 80% r. H. or less (no condensation) | |||||
Withstanding voltage | 2.21 kVAC for 5 s (between the core and the case) | |||||
Power supply | Four AA-size alkaline batteries (1.5V LR6); battery life approx. 60 h (continuous) backlight off and LED light off | |||||
Other functions | Data hold, zero adjust function, auto power-off, LED torch light, back light display, illuminant panel | |||||
Safety standards | EN61010-1, EN61010-2-030, EN61010-2-032 | |||||
Dimensions (WxHxD, mm) | 61 x 111 x 40, approx. 290 g (including batteries) |
Note The quality test certificate QIC has to be ordered together with the hardware with the initial purchase. Later orders of the QICs are not possible!