Options and Accessories for Ceyear Spectrum Analyzers 4051(-S)
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads
Options and Accessories for the Ceyear Spectrum Analyzer Series 4051 and 4051-S (Economy)
Model Overview
Model/ordering code | Description - options | For models... |
4051-OPT-H01 | Back RF input | Standard series |
4051-OPT-H02 | High IF output, output secondary IF signal, output frequency range 275 MHz...475 MHz, step resolution 1 Hz | Standard series |
4051-OPT-H03 | IF output; output third IF signal, output frequency range 10 MHz...160 MHz, step resolution 1 Hz | Standard and economy/-S series |
4051-OPT-H04A | Reconstruct IF/video signal output; IF, AM/FM or I/Q signal output in form of digital reconstruction; bandwidth upper limit 40 MHz (note: H04A and H04B can be selected at the same time) | Standard series |
4051-OPT-H04B | Wide band reconstruct IF/video signal output; IF, AM/FM or I/Q signal output in form of digital reconstruction; bandwidth range 50 MHz...100 MHz (note: H04B can only be selected when option H38B with 200 MHz broadband is selected; H04A and H04B can be selected together) | Standard series |
4051-OPT-H08 | Wide log detect output of the logarithm wave-detection signal which can reflect the input signal level characteristics | Standard and economy/-S series |
4051-OPT-H12A | 40 MHz bandwidth digital interface; to output real-time broadband collecting data through optical fiber, support max. 400 MHz bandwidth signal data output (note: H12A cannot be selected when H38B has been selected; once this option is selected, H12B and H39 cannot be selected) | Standard series |
4051-OPT-H12B | 200 MHz bandwidth digital interface; to output real-time broadband collecting data through optical fiber, support max. 200 MHz bandwidth signal data output (note: H12B can only be selected when option H38B with 200 MHz broadband is selected?once this option is selected, H12B and H39 cannot be selected? | Standard series |
4051-OPT-H15 | +24 VDC power supply | Standard series |
4051-OPT-H22A | 4711 SSD data recorder (have same interface characteristics) to realize real-time large-capacity recording of signal data (note: A22A can only be selected together with H12A or H12B) | Standard series |
4051-OPT-H22B | 4712 HDD data recorder (have same interface characteristics) to realize real-time large-capacity recording of signal data (note: A22B can only be selected together with H12A or H12B) | Standard series |
4051-OPT-H33 | Electronic attenuator; frequency range: 3 Hz...4 GHz, attenuation range: 30 dB, 1 dB steps | Standard series |
4051-OPT-H34-04 | Low-noise preamplifier; can select low-waveband preamplifier or full-waveband preamplifier. When you select full-waveband preamplifier, we provide above 4 GHz frequency band noise optimization path (note: The number of low-waveband preamplifier is H34-04. The full-waveband preamplifier should be selected according to the frequency upper limit of the main unit. For example, the max. frequency of 4051E is 26.5 GHz, then the full-waveband preamplifier H34-26 should be selected) | Standard series and economy/-S series |
4051-OPT-H34-09 | Low-noise preamplifier | Standard series and economy/-S series |
4051-OPT-H34-13 | Low-noise preamplifier | Standard series and economy/-S series |
4051-OPT-H34-18 | Low-noise preamplifier | Standard series and economy/-S series |
4051-OPT-H34-26 | Low-noise preamplifier | Standard series and economy/-S series |
4051-OPT-H34-40 | Low-noise preamplifier | Standard series |
4051-OPT-H34-45 | Low-noise preamplifier | Standard series |
4051-OPT-H34-50 | Low-noise preamplifier | Standard series |
4051-OPT-H36 | Preselector bypass; the tracking pre-selector in the bypass receiving channel (note: Option H36 required together with H38A or H38B to provide the best wideband signal receiving characteristics) | Standard series |
4051-OPT-H38A | Support 10 Hz...40 MHz analysis bandwidth (note: Option H38B and option H36 should be selected together to provide the best wideband signal receiving characteristics, H38B and H38A are no need to be selected at the same time) | Standard series |
4051-OPT-H38B | Support 10 Hz...200 MHz analysis bandwidth (note: Option H38B/C and option H36 should be selected together to provide the best wideband signal receiving characteristics) | Standard series |
4051-OPT-H38C | Support 10 Hz...550 MHz analysis bandwidth (note: Option H38B/C and option H36 should be selected together to provide the best wideband signal receiving characteristics) | Standard series |
4051-OPT-H39 | Audio analyzer; audio frequency signal parameter measurement, distortion measurement and waveform analysis (note: Option H12A and H12B cannot be selected when selecting this option) | Standard series |
4051-OPT-H40 | External mixer, to extend the frequency range using external frequency mixing method. This option provides LO output and IF input, as well as signal recognition ability (note: The extended frequency range depends on the selected extension module which has to be ordered additionally) | Standard series except 4051A |
4051-OPT-H41 | Real-time spectrum analyzer; this option provides digital phosphor spectrum and seamless waterfall, including frequency template trigger, which can support real-time spectrum analysis of 200 MHz bandwidth (note: Max. real-time analysis bandwidth depends on 4051-H38A, 4051-H38B options) | Standard series except 4051L |
4051-OPT-H48 | Noise figure; noise source drive and noise figure measurement function (note: H34 low-noise preamplifier option and corresponding 1660X noise source sensor needed) | Standard series |
4051-OPT-H97 | Mounting suit; handles and accessories for 4051 mounting on standard racks | Standard series and economy/-S series |
4051-OPT-H99 | High-strength lightweight aluminum transportation case, with handle and roller, convenient for transportation | Standard series and economy/-S series |
Related Products