Options and Accessories for Ceyear Spectrum Analyzers 4051(-S)

Options, accessories for Ceyear Spectrum Analyzers 4051 and 4051-S (Economy)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Options and Accessories for the Ceyear Spectrum Analyzer Series 4051 and 4051-S (Economy)

Model Overview

Model/ordering codeDescription - optionsFor models...
4051-OPT-H01Back RF inputStandard series
4051-OPT-H02High IF output, output secondary IF signal, output frequency range 275 MHz...475 MHz, step resolution 1 HzStandard series
4051-OPT-H03IF output; output third IF signal, output frequency range 10 MHz...160 MHz, step resolution 1 HzStandard and economy/-S series
4051-OPT-H04AReconstruct IF/video signal output; IF, AM/FM or I/Q signal output in form of digital reconstruction; bandwidth upper limit 40 MHz (note: H04A and H04B can be selected at the same time)Standard series
4051-OPT-H04BWide band reconstruct IF/video signal output; IF, AM/FM or I/Q signal output in form of digital reconstruction; bandwidth range 50 MHz...100 MHz (note: H04B can only be selected when option H38B with 200 MHz broadband is selected; H04A and H04B can be selected together)Standard series
4051-OPT-H08Wide log detect output of the logarithm wave-detection signal which can reflect the input signal level characteristicsStandard and economy/-S series
4051-OPT-H12A40 MHz bandwidth digital interface; to output real-time broadband collecting data through optical fiber, support max. 400 MHz bandwidth signal data output (note: H12A cannot be selected when H38B has been selected; once this option is selected, H12B and H39 cannot be selected)Standard series
4051-OPT-H12B200 MHz bandwidth digital interface; to output real-time broadband collecting data through optical fiber, support max. 200 MHz bandwidth signal data output (note: H12B can only be selected when option H38B with 200 MHz broadband is selected?once this option is selected, H12B and H39 cannot be selected?Standard series
4051-OPT-H15+24 VDC power supplyStandard series
4051-OPT-H22A4711 SSD data recorder (have same interface characteristics) to realize real-time large-capacity recording of signal data (note: A22A can only be selected together with H12A or H12B)Standard series
4051-OPT-H22B4712 HDD data recorder (have same interface characteristics) to realize real-time large-capacity recording of signal data (note: A22B can only be selected together with H12A or H12B)Standard series
4051-OPT-H33Electronic attenuator; frequency range: 3 Hz...4 GHz, attenuation range: 30 dB, 1 dB stepsStandard series
4051-OPT-H34-04Low-noise preamplifier; can select low-waveband preamplifier or full-waveband preamplifier. When you select full-waveband preamplifier, we provide above 4 GHz frequency band noise optimization path (note: The number of low-waveband preamplifier is H34-04. The full-waveband preamplifier should be selected according to the frequency upper limit of the main unit. For example, the max. frequency of 4051E is 26.5 GHz, then the full-waveband preamplifier H34-26 should be selected)Standard series and economy/-S series
4051-OPT-H34-09Low-noise preamplifierStandard series and economy/-S series
4051-OPT-H34-13Low-noise preamplifierStandard series and economy/-S series
4051-OPT-H34-18Low-noise preamplifierStandard series and economy/-S series
4051-OPT-H34-26Low-noise preamplifierStandard series and economy/-S series
4051-OPT-H34-40Low-noise preamplifierStandard series
4051-OPT-H34-45Low-noise preamplifierStandard series
4051-OPT-H34-50Low-noise preamplifierStandard series
4051-OPT-H36Preselector bypass; the tracking pre-selector in the bypass receiving channel (note: Option H36 required together with H38A or H38B to provide the best wideband signal receiving characteristics)Standard series
4051-OPT-H38ASupport 10 Hz...40 MHz analysis bandwidth (note: Option H38B and option H36 should be selected together to provide the best wideband signal receiving characteristics, H38B and H38A are no need to be selected at the same time)Standard series
4051-OPT-H38BSupport 10 Hz...200 MHz analysis bandwidth (note: Option H38B/C and option H36 should be selected together to provide the best wideband signal receiving characteristics)Standard series
4051-OPT-H38CSupport 10 Hz...550 MHz analysis bandwidth (note: Option H38B/C and option H36 should be selected together to provide the best wideband signal receiving characteristics)Standard series
4051-OPT-H39Audio analyzer; audio frequency signal parameter measurement, distortion measurement and waveform analysis (note: Option H12A and H12B cannot be selected when selecting this option)Standard series
4051-OPT-H40External mixer, to extend the frequency range using external frequency mixing method. This option provides LO output and IF input, as well as signal recognition ability (note: The extended frequency range depends on the selected extension module which has to be ordered additionally)Standard series except 4051A
4051-OPT-H41Real-time spectrum analyzer; this option provides digital phosphor spectrum and seamless waterfall, including frequency template trigger, which can support real-time spectrum analysis of 200 MHz bandwidth (note: Max. real-time analysis bandwidth depends on 4051-H38A, 4051-H38B options)Standard series except 4051L
4051-OPT-H48Noise figure; noise source drive and noise figure measurement function (note: H34 low-noise preamplifier option and corresponding 1660X noise source sensor needed)Standard series
4051-OPT-H97Mounting suit; handles and accessories for 4051 mounting on standard racksStandard series and economy/-S series
4051-OPT-H99High-strength lightweight aluminum transportation case, with handle and roller, convenient for transportationStandard series and economy/-S series