Tekbox TBRX101 Loop Antennas for MIL-STD-461G RE101 Testing
Tekbox TBRX101 Loop Antennas for MIL-STD-461G RE101 Testing
Tekbox TBRE101 Passive Receiving Loop Antenna
The Tekbox TBRE101 is a passive receiving loop antenna used in MIL-STD-461G RE101 testing to measure radiated emissions from electronic equipment and subsystems, including electrical cable interfaces for defense applications. The TBRE101 is used to measure low frequency magnetic field emissions 7 cm from all sides of the DUT.
Tekbox TBRS101 Loop Antenna
The Tekbox TBRS101 loop antenna set consists of the TBRS101-TX radiating loop, TBRS101-RX field monitoring loop and ▸TBCCP1-2K70.
The TBRS101-TX radiating loop is used to generate the low frequency magnetic field emissions. The distance between the winding and EUT is 5 cm. This is accomplished when the front edge of the the radiating loop comes into contact with the EUT faces during testing.
The TBRS101-RX field monitoring loop receives magnetic field radiation normal to the containing plane 5 cm from the TBRS101-TX radiating loop winding and produces a voltage signal proportional to the intensity of the B-field/H-field radiation at the loop's output port.
Model Overview
Model | TBRE101 | TBRS101-TX | TBRS101-RX |
Type | Receiving loop antenna | Radiating loop antenna | Passive monitoring loop antenna |
Frequency range | 30 Hz...100 kHz (usable frequency range 10 Hz...1 MHz) | 30 Hz...100 kHz | 30 Hz...100 kHz |
Standards | MIL-STD-461G/RE101 | MIL-STD-461G/RS101 | MIL-STD-461G/RS101 |
Loop construction | 36 turns of 7 strand 41 AWG Litz wire; diameter 13.3 cm | 20 turns of 12 AWG Gauge 2mm copper wire; diameter: 12 cm | 51 turns of 7 strand 41 AWG Litz wire; diameter: 4.1 cm |
DC resistance of the loop coil | 10 Ω (nominal) | 50 mΩ (nominal) | 4.1 Ω (nominal) |
Self inductance of the loop coil | 385 µH | 90 µH | 180 µH |
Output connector | N-female, 50Ω | Male banana plugs | N-female, 50Ω |
Antenna conversion factor | Within ±3 dB compared to the theoretical validation factor for standard RE101 loop in MIL-STD-461G | - | Within ±3 dB compared to the theoretical validation factor for standard RS101 field monitoring loop in MIL-STD-461G |
Dimensions (mm, LxWxH) | 106 x 152 x 191; 0.5 kg | 82 x 152 x 152 (No mounting pole)/380 x 152 x 152 (mounting pole); 0.5 kg) | 437 x 542 x 792; 0.1 kg |
Optional accessories, sets | TBRS101-TX: Radiating loop for generating magnetic fields in the range of 30 Hz...100 kHz; TBCCP1-2K70: Coaxial RF current monitoring probe for measuring the injected current into the radiating loop; TBMR-110M: 1 Hz...110 MHz measurement receiver, CISPR 16 and MIL-STD-461 | TBRS101-SET: Set of TBRS101-TX, TBCCP1-2K70, and accessories |
Frequently Asked Questions:
Question: What does MIL-STD-461G RS10 mean?
Answer: The MIL-STD-461G RS101 test determines the susceptibility of equipment installed in close proximity to large radiated magnetic fields, and their ability to withstand them in the frequency range 30 Hz...100 kHz.