TekBox TBMDA3B, 4B, 5 Modulated Power Amplifiers

starting 1.157,87
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Benefits of the TBMDA Series Power Amplifiers up to 75, 400 MHz, or 1 GHz

  • Modulated amplifiers for immunity testing/EMC pre-compliance.
  • TBMDA5 generates test levels class 1 and class 2 according to ISO/EN 61000-4-6.
  • 1 kHz, 80% AM and 50% duty cycle pulse modulation and more.

TekBox TBMDA3B, 4B, 5 Modulated Power Amplifiers

TekBox Models TBMDAB3, TBMDA4B, TBMDA5 Signal Sources/Amplifiers for Immunity Testing

The TekBox models TBMDA3B, TBMDA4B, TBMDA5 are signal sources/modulated power amplifiers for immunity testing. They are designed to be driven by the tracking generator output of spectrum analyzers. The devices are the ideal solution to drive TekBox near field probes in order to find the sensitive spot of an electronic circuit or to create electric fields when driving TekBox TEM cells.

The TBMDA5 provides the necessary power, bandwidth and modulation for conducted immunity testing using CDNs in the frequency range from 150 kHz to 400 MHz. With a 1 dB compression point of up to 2.5 W in the frequency range 150 kHz to 400 MHz it can generate test levels class 1 and class 2 according to ISO/EN 61000-4-6.

  • CW amplifier (modulation off).
  • 1 kHz, 80% AM modulation.
  • 1 kHz, 50% duty cycle pulse modulation.
  • 217 Hz, 12.5% duty cycle pulse modulation.

Model Overview

ModelTBMDA3B1)TBMDA4B1)TBMDA5
Input/output50  Ω, N female
Supply voltage range110...240 V
Frequency range10 MHz...1 GHz100 kHz...75 MHz150 kHz...400 MHz, usable from 100 kHz to 1.2 GHz;
small signal gain: 38 dB typ.
gain flatness 150 kHz...400 MHz/Pin = -5 dBm: 3.5 dB typ.
Additional specifications...such as saturated output power, 1-dB output compression point, total harmonic distortion at various frequencies, see full datasheets
Third order intercept point44 dBm at 100 MHz, ∆f = 2 MHz typ.+53 dBm at 25 MHz, Δf = 200 kHz typ.+43 dBm at 100 MHz, Δf = 2 MHz, typ.
Noise figure9 dBAt 35 MHz: 7.2 dBAt 100 MHz: 6.1 dB
Modulation1 kHz, 80% AM; 1 kHz, 50% duty cycle pulse modulation; 217 Hz, 12.5% duty cycle pulse modulationAM - internal modulation frequency 1 kHz ±20%;
PM - internal modulation frequency 1 kHz ±10%, 217 Hz ±20%;
duty cycle, PM: 50% ±10% at 1 kHz; 12.5% ±20% at 217 Hz
AM - internal modulation frequency 1 kHz ±20%;
PM - internal modulation frequency 1 kHz ±20%, 217 Hz ±20%;
duty cycle, PM: 50% ±10% at 1 kHz; 12.5% ±20% at 217 Hz
Operating temperature range-20...+50°C
Applications
  • General purpose power amplifier.
  • Signal source for immunity testing, driving near field probes.
  • Signal source for immunity testing, driving TEM cells.
  • General purpose power amplifier.
  • Signal source for immunity testing, driving near field probe.
  • Signal source for immunity testing, driving TEM cells.
  • General-purpose wideband RF power amplifier.
  • Wideband RF power amplifier for conducted immunity testing driving CDNs or BCI-probes.
  • Wideband RF power amplifier for radiated immunity testing, driving near field probes.
  • Wideband RF power amplifier for radiated immunity testing, driving TEM cells.

1) Replacement for the EOL version TBMDA3 or TBMDA4.

Customers also bought