Benefits of the TekBox TBL5000 LISN Series Stabilisation Networks

  • For the measurement of line-conducted interferences and noise measurements.
  • Series for the frequency range 9 kHz to 30 MHz.
  • The ideal solution for pre-compliance EMC testing according to CISPR16-1-2, etc.

TekBox TBL5000 LISN Series Line Impedance Stabilization Networks

TekBox Models TBL5016-1, TBL5016-2, TBL5016-3, TBL5032-3 30 MHz LISNs

  • TBL5016-1 50 µH 16 A LISN for conducted noise measurements of DC or AC-powered electronic equipment. Designed according to CISPR16-1-2 and MIL-STD-461F standard.
  • TBL5016-2 50 µH 16 A LISN for line-conducted interference, according to CISPR16-1-2. Designed for testing single phase, AC-powered equipment with supply voltages up to 240 V and 16 A. Conducted noise can be measured on the phase and on the neutral conductor. Equipped with a switchable limiter/attenuator.
  • TBL5016-3 50 µH 16 A LISN for the measurement of line-conducted interference, according to CISPR16-1-2. Designed for testing 3-phase and single-phase, AC-powered equipment with supply voltages up to 450 V/260 V and 16 A. Conducted noise can be measured on each phase and on the neutral conductor. The TBL5016-3 has separate RF outputs for each phase and neutral and consequently can be coupled with the TBLM1 to split the emissions in its common mode and differential mode components.
  • TBL5032-3 50 µH 32 A LISN for the measurement of line-conducted interference, according to CISPR16-1-2. Designed for testing 3-phase and single phase, AC-powered equipment with supply voltages up to 450 V/260 V and 32 A. Conducted noise can be measured on each phase and on the neutral conductor. The TBL5032-3 has separate RF outputs for each phase and neutral and consequently can be coupled with the TBLM1 to split the emissions in its common mode and differential mode components. The TBL5032-3 has no integrated high pass filter at the RF outputs, but comes with an external 9 kHz coaxial high pass instead.

Model Overview

ModelTBL5016-1TBL5016-2TBL5016-3TBL5032-3
Frequency range9 kHz...30 MHz
Impedance50 Ω||(50 µH + 5 Ω)
More specs
  • 16 A LISN
  • 1 path
  • CISPR16-1-2, MIL-STD461F
  • LISN type: V-AMN, configurable as 50 Ω/50 µH + 5 Ω or 50 Ω/50 µH
  • Maximum current: 16 A continuous
  • Operating voltage range: 0...250 VDC; 0...250 VAC (50/60 Hz), 0...120 VAC (400 Hz)
  • Fuse: 2x 16 A slow
  • High current plug/screw terminals - male: Phoenix Contact 1998933, female: Phoenix Contact 1967375
  • Dimensions (mm): 250 x 225 x 140 (incl. ground brackets); 2.7 kg
  • 16 A LISN
  • 2 paths
  • CISPR16-1-2
  • Artificial hand: 220 pF + 511 Ω
  • Switchable PE: 50 Ω||50 µH
  • Limiter/attenuator: 150 kHz...30 MHz; 10 dB
  • Air core inductors
  • Line voltage: max. 240 V/50...60 Hz
  • Max. current: 16 A at 23°C
  • DUT socket: Country specific
  • Measurement connector: 50 Ω BNC
  • Power connector: IEC 60320 C19
  • Operating temperature: +5...+40°C; 5...80% rel. humidity
  • Safety: Safety Class I, IEC 1010-01
  • 16 A LISN
  • 4 paths
  • CISPR16-1-2
  • Artificial hand: 220 pF + 511 Ω
  • Switchable PE: 50 Ω||50 µH
  • 250 µH pre-filter
  • Separate RF outputs for each line and neutral
  • Air core inductors
  • Line voltage: max. 540 V/260 V/50...60 Hz, CAT II
  • Max. current per line and neutral: 16 A at 23°C each
  • 3-phase DUT socket: CEE/IEC60309, 3L+N+PE, 16 A, female
  • Single-phase DUT socket: Country specific
  • Power connector: CEE/IEC60309, 3L+N+PE, 16 A, male
  • Measurement connectors: 50 Ω BNC
  • Operating temperature: +5...+40°C; 5...80% rel. humidity
  • Safety: Safety Class I, IEC 1010-01
  • 32 A LISN
  • 4 paths
  • CISPR16-1-2
  • Artificial hand: 220 pF + 511 Ω
  • Switchable PE: 50 Ω||50 µH
  • 250 µH pre-filter
  • Separate RF outputs for each line and neutral
  • Air core inductors
  • Line voltage: max. 540 V/260 V; 50...60 Hz, CAT II
  • Max. current per line and neutral: 32 A at 23°C each
  • 3-phase DUT socket: CEE/IEC60309, 3L+N+PE, 32A, female
  • Single-phase DUT socket: country specific
  • Power connector: CEE/IEC60309, 3L+N+PE, 32A, male
  • Measurement connectors: 50 Ω BNC
  • External 9 kHz high pass filter, N-male/N-female
  • Operating temperature: +5...+40°C; 5...80% rel. humidity

Customers also bought