Siglent SHN900A Series Handheld Vector Network Analyzers
Benefits of the SHN900 Vector Network Analyzers up to 26.5 GHz
- Very compact 2-port VNAs up to 26.5 GHz.
- Many features included (GPS, CAT etc.), optional spectrum analysis and time domain analysis.
- 8.4"/21.3 cm touch screen; USB and LAN interfaces standard.
Siglent SHN900A Series Handheld Vector Network Analyzers
Models Siglent SHN914A, SHN920A, SHN926A Portable 2-Port VNAs
The Siglent SHN900A is a series of VNA/vector network analyzers with a frequency range of 30 kHz to 14, 20, or 26.5 GHz. The devices support 2 port scattering parameter, differential parameter, and time domain parameter measurements. The SHN900A series instruments can determin the Q factor, bandwidth, and insertion loss of a filter. They feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear frequency mode, log frequency mode, power sweep mode, CW time mode, and segment sweep mode. The SHN900A series VNAs also support scattering parameter correction/calibration of SOLT, SOLR, TRL, response, and enhanced response for increased flexibility in R&D and manufacturing applications.
- Very compact, handy handheld VNA.
- Frequency range 30 kHz...26.5 GHz.
- Frequency resolution 1 Hz.
- Level resolution 0.01 dB.
- Range of IFBW 10 Hz...3 MHz.
- Setting range of output level -45...+10 dBm.
- Dynamic range typ. 110 dB.
- Types of calibration:
- Response calibration,
- enhanced response calibration,
- full-one port calibration,
- full-two port calibration,
- TRL calibration.
- Types of measurement:
- Scattering-parameter measurement,
- differential-parameter measurement,
- receiver measurement,
- time-domain parameter analysis,
- limit test,
- ripple test,
- impedance conversion,
- fixture simulation,
- adaptor removal/insertion,
- spectrum analysis frequency offset,
- scalar mixer measurement,
- pulse measurement.
- Internal bias-tee connections.
- Support GPS, time and location information saving.
- Interface: LAN, USB device, USB host (USB-GPIB).
- Remote control: SCPI, LabVIEW, IVI based on USB-TMC, VXI-11, Socket, Telnet, WebServer.
- 8.4"/21.3 cm touch screen, mouse, keyboard.
- Multi-window display, up to 256 channels/256 measurement windows/64 test traces per window).
Model Overview
Model | SHN914A | SHN920A | SHN926A |
Frequency range | 30 kHz...14 GHz | 30 kHz...20 GHz | 30 kHz...26.5 GHz |
Ports | 2 | 2 | 2 |
Frequency resolution | 1 Hz | ||
Level resolution | 0.01 dB | ||
Range of IFBW | 10 Hz...3 MHz | ||
Setting range of output level | -45...+10 dBm | ||
Dynamic range | 100 dB (specification), 110 dB (typical) | ||
Types of calibration | Response calibration, enhanced response calibration, full-one port calibration, full-two port calibration, TRL calibration | ||
Types of measurement | (Standard and optional) Scattering parameter measurement, differential parameter measurement, receiver measurement, time domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion, enhanced time domain parameter analysis (TDR), spectrum analysis, frequency offset, scalar mixer measurement, pulse measurement | ||
Bias-Tees | Standard | ||
GPS | Standard | ||
CAT/DTF measurement | Standard | ||
Options | SHN900-SA: Spectrum analysis; SHN900-TDA: Time domain analysis; SHN900-TDR: Enhanced time domain analysis | ||
Interface | LAN/Ethernet (10/100Base, RJ45), USB 2.0 device, USB 2.0 host (USB-GPIB); supported: Mouse, keyboard | ||
Remote control | SCPI, LabVIEW, IVI based on USB-TMC, VXl-11, Socket, Telnet, Webserver | ||
Power supply | Rechargeable lithium battery, AC-DC adaptor included; 4 hours | ||
Display | 8.4"/21.3 cm touch screen | ||
Dimensions (mm) | 310 x 215 x 79; 3.2 kg |
Included: Handheld VNA SHN 914A, 920A, or 926A, quick start, USB type C cable, rechargeable lithium battery, AC-DC adaptor, portable bag.
Options and Accessories
Model | Description |
SHN900-TDA | TDA option: Time domain analysis |
SHN900-TDR | TDR option: Enhanced time domain analysis |
SHN900-SA | SA option: Spectrum analysis |
F603ME | 3.5 mm, male, 50-Ω calibration kit, 0...4.5 GHz |
F603FE | 3.5 mm, female, 50-Ω calibration kit, 0...4.5 GHz |
F604MS | 3.5 mm, male, 50-Ω calibration kit, 0...9 GHz |
F604FS | 3.5 mm, female, 50-Ω calibration kit, 0...9 GHz |
F604TS | 3.5 mm, male and female, 50-Ω calibration kit, 0...9 GHz |
F606TS | 3.5 mm, male and female, 50-Ω calibration kit, 0...26.5 GHz |
SEM5000A | Electronic calibration kit |
SNA-TB01 | RF test demo board |
ADP-18 | Adjustable differential TDR probe DC...18 GHz |
ADP-26 | Adjustable differential TDR probe DC...26.5 GHz |
ASP-18 | Adjustable differential TDR probe DC...18 GHz |
ASP-26 | Adjustable differential TDR probe DC...26.5 GHz |
SMA-SMA-18L | SMA(M)-SMA(M) cable DC...18 GHz, 1000 mm |
SMA-SMA-26L | SMA(M)-SMA(M) cable DC...26.5 GHz, 1000 mm |
SMAF-SMA-26L | SMA(F)-SMA(M )cable DC...26.5 GHz, 1000 mm |
V26-N35MN35F-25IN | NMD 3.5 female-NMD 3.5 male DC...26.5 GHz, 635 mm |
V26-N35FA35F-25IN | NMD 3.5 female-APC 3.5 female DC...26.5 GHz, 635 mm |
USB-GPIB | USB-GPIB adaptor |
ANT-GPS1 | GPS antenna, SMA(M), 1000 mm |
Related Products