Siglent SDS2000X HD Series 12 bit High Resolution Oscilloscopes
Benefits of the SDS2104X-HD, SDS2204X-HD, and SDS2354X-HD High-Accuracy Mixed-Signal Oscilloscopes
- True 12-bit high resolution for more signal details.
- Low noise floor and high accuracy.
- 100, 200, 350, or 500 MHz1) bandwidth and advanced features.
Siglent SDS2000X HD Series 12 bit High Resolution Oscilloscopes
With the SDS2000X-HD Siglent enhances the commen oscilloscope ADC resolution of 8 bit to true 12 bit. This makes resolution accuracy 16 times higher than on common 8-bit oscilloscopes and shows more signal details. The oscilloscopes have bandwidths up to 350 MHz, upgradeable to 500 MHz1). Other partly standard or optional features are MSO-capability (mixed-signal/logic analyzer), a built-in arbitraty waveform generator, 2-Mpts hardware-accelerated FFT, Bode plot function, serial bus trigger and decode (many as standard, additional ones as software options), and more. The wide and clear 10.1"/25.65 cm TFT LCD with multi-touch gesture touch screen makes the devices easy-to-use.
- High sampling rate with 12-bit ADCs (enhanced resolution to 15 bit). Resolution accuracy 16 times higher than on common 8-bit oscilloscopes.
- Front ends with lower noise floor: 70 µVRMS at 500 MHz bandwidth and 0.5% DC gain accuracy.
- "Cleaner"/"clearer" waveform display showing more signal details and allowing more accurate waveform measurements.
- 100 MHz, 200 MHz, or 350 MHz bandwidth, upgradeable to 500 MHz1).
- 100,000 Wfms/s waveform capture rate.
- Deep record length of 200 Mpts.
- Automatic measurements on more than 50 parmeters.
- History waveform playback.
- Mixed-signal (MSO) function.
- Additional features and options: Bode plot; hardware-accelerated FFT up to 2 Mpts; power analysis; serial bus trigger and decode.
- 10.1"/25.65 cm TFT LCD with capacitive multi-touch gesture touch screen.
- Interfaces: USB Host and Device, Ethernet/LAN.
- Built-in web-server supports remote control.
- Applications:
Measuring high-precision sensors and actuators.
Medical equipment.
Laser pulses.
RF signals/modulated signals.
Power measurement.
and more.
Model Overview
Model | SDS2104X-HD EOL/obsolete | SDS2204X-HD | SDS2354X-HD | |
Analog channels | 4 | |||
Bandwidth | 100 MHz | 200 MHz | 350 MHz | |
Resolution | 12 bit; HiRes/ERES 3 bit hardware-based | |||
Sample rate | 2 GS/s (interleaving), 1 GS/s (non-interleaving) | |||
Memory depth | 200 Mpts | |||
Waveform capture rate | 100,000 Wfms/s (normal); 500,000 Wfms/s (sequence mode) | |||
Accuracy | DC gain 0.5 mV/Div...4.95 mV/Div: ±1.5%; 5 mV/Div...10 V/Div: ±0.5% Time base ±2 ppm (initial); ±0.5 ppm (1st year aging); ±3 ppm (20-year aging) | |||
Noise floor | 70 µVRMS at 500 MHz | |||
SFDR | ≥45 dBc | |||
Channel-to-channel isolation | >60 dBc, <500 MHz >70 dBc, <350 MHz | |||
Trigger | Edge, slope, pulse, window, runt, interval, dropout, pattern, video, qualified, nth edge, delay, setup/hold time, serial; serial trigger and decode standard: I2C, SPI, UART, CAN, LIN; optional: CAN FD, FleyRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only) | |||
Sequence | Up to 80,000 segments | |||
History | Up to 80,000 frames | |||
Digital channels (MSO option) | 16; max. 500 MS/s max. waveform capture rate; record lenght up to 50 Mpts (additional MSO probes required) | |||
Additional features | Bode plot; hardware-accelerated FFT up to 2 Mpts, 7-digits counter, digital multimeter | |||
Arbitrary waveform generator | Built-in, 25 MHz (software option); 125 MS/s sample rate, 16 kpts waveform memory | |||
Display | 10.1"/25.65 cm TFT-LCD capacitive touch-screen with multi-touch gestures | |||
Interfaces | USB Host and Device, Ethernet/LAN; built-in web-server |
Included: Siglent SDS 2104X HD, 2204X HD, or 2354X HD, power cord, USB cable, 4x passive probe, quick start guide, certificate of calibration, wireless mouse.
Options and Accessories
Model | Description |
SDS2000HD-FG | 25 MHz built-in function generator option (software) |
SDS2000HD-16LA | Mixed-signal (MSO) function (software), 500 MS/s, additional SPL2016 probe required |
SPL2016 | MSO logic probe, 16 channel |
SDS2000HD-PA | Power analysis: Power quality, current harmonics, inrush current, switching loss, slew rate, modulation, output ripple, turn on/off, transient response, PSRR, efficiency |
DF2001A | Deskew fixture for voltage and current probe |
SDS2000HD-I2S | I2S trigger and decode (software) |
SDS2000HD-1553B | MIL-STD-1553B trigger and decode (software) |
SDS2000HD-FlexRay | FlexRay trigger and decode (software) |
SDS2000HD-CANFD | CAN FD trigger and decode (software) |
SDS2000HD-SENT | SENT trigger and decode (software) |
SDS2000HD-Manch | Manchester decode (software) |
SDS2000HD-BW1T2 | Upgrade bandwidth from 100 MHz to 200 MHz |
SDS2000HD-BW1T3 | Upgrade bandwidth from 100 MHz to 350 MHz |
SDS2000HD-BW1T5 | Upgrade bandwidth from 100 MHz to 500 MHz1) |
SDS2000HD-BW2T3 | Upgrade bandwidth from 200 MHz to 350 MHz |
SDS2000HD-BW2T5 | Upgrade bandwidth from 200 MHz to 500 MHz1) |
SDS2000HD-BW3T5 | Upgrade bandwidth from 350 MHz to 500 MHz1) |
1) Note: 500 MHz available only when ADCs are in interleaved mode (2 GS/s). When ADCs work in non interleaved mode, bandwidth is limited to 350 MHz.
Related Products