Pico Technology AD2201, AC2801 Active, Differential Probes
Benefits of the AD2000 Active Probes up to 200 MHz or 800 MHz, with BNC
- Differential oscilloscope probes for high-speed measurement applications.
- Bandwidth up to 200 or 800 MHz.
- Common-mode range up to ±30 or ±60 V.
Pico Technology AD2201, AC2801 Active, Differential Probes
The Pico Technology AD2201 (200 MHz) and AD2801 (800 MHz) are active differential probes suitable for high-speed measurement applications. These differential probes extend the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making differential voltage measurements. Applications include making safe measurements in power circuit applications and acquisition of high-speed balanced differential signals found in serial communications buses.
- Differential oscilloscope probes up to 200 MHz or 800 MHz.
- Differential measurement range of ±15 V or ±20 V.
- Common-mode range of up to ±30 V or ±60 V (DC + peak AC).
- Include an in-line battery module, with a 5 V USB power lead integrated for use with standard off-the-shelf USB chargers.
Model Overview
Model | AD2201 differential oscilloscope probe | AD2801 differential oscilloscope probe | |
Ordering code | TA488 | TA489 | |
Replacement for... | TA045 | TA046 | |
Bandwidth | DC...200 MHz (–3 dB) | DC...800 MHz (twin pin configuration) | |
Attenuation ratio | 10:1 | 10:1 | |
Accuracy | ±1% | ±2% | |
Rise time | 1.75 ns | n.s. | |
Input impedance | 500 kΩ || 7 pF each side to ground | 100 kΩ || 2 pF | |
Input voltage | Differential range ±20 V; common mode range ±60 V; absolute max. voltage (either input to ground) ±60 V | Max. differential ±15 V; max. common mode ±30 V; absolute max. voltage ±40 V | |
Output | Swing (into 50 kΩ load) ±2 V; offset (typical) <±2 mV; noise (typical) 0.3 mVRMS; source impedance (typical) 50 Ω; CMRR (typical) 80 dB at 100 Hz; 50 dB at 10 MHz; | Swing (into 50 Ω load) ±1.5 V; offset (typical) <±5 mV; noise (typical) 0.3 mVRMS; output impedance (typical) 50 Ω; CMRR (typical) 60 dB at 60 Hz; 15 dB at 500 MHz | |
Power requirements | USB power lead 5 VDC/300 mA; battery 9 V (PP3, 6LR61); mains adaptor(s) 5 VDC/300 mA or 9 VDC/200 mA | USB power lead 5 VDC/300 mA; battery 9 V (PP3, 6LR61); mains adaptor(s) 6 VDC/500 mA or 9 VDC/300 mA | |
Length | Input leads 50 cm, BNC lead 125 cm | Output BNC cable length 1.2 m | |
Weight | 300 g | 130 g | |
Dimension (mm) | 111 x 22 x 14 | 111 x 22 x 14 | |
Temperature | -10...+40°C operating/-30...+70°C storage | ||
Compliance | Designed and tested in accordance with the European standard publication EN 61010-031:2015 (Safety requirements for hand-held probe assemblies for electrical measurement and test) | ||
Kit includes | AD2201 probe, test hooks (pair, red/black), crocodile clip (pair, red/black), 9 V battery, USB power cable (mains adaptor not included) | AD2801 probe body, power unit and BNC assembly, test wires (2x pair, red/black, 0.8 mm x 70 mm and 0.8 mm x 130 mm), large grabbers (pair, red/black, 5 mm wide), small grabbers (pair, red/black, 2.5 mm wide), test tips (0.8 mm, 6 pcs), 2-pin prods (assorted lengths, 3 pcs), 9 V battery, USB power cable |
Information on product safety:
Manufacturer:
Pico Technology Ltd., James House, Colmworth Business Park, St Neots, Cambridgeshire, PE19 8YP/GBR
www.picotech.com
Responsible person:
Meilhaus Electronic GmbH, Am Sonnenlicht 2, 82239 Alling/DEU
info@meihaus.com