Keysight N9000B CXA Signal Analyzer, 9kHz to 26.5GHz

starting 20.827,38
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the N9000B CXA Spectrum Analyzer with Multi-Touch Display

  • Signal/spectrum analyzer up to 26.5 GHz.
  • Various options such as pre-amp., tracking generator, advanced measurements.
  • Wide touch-screen display and LAN, USB, GPIB interfaces.

Keysight N9000B CXA Signal Analyzer, 9 kHz to 26.5 GHz

Design, test and educate with an intuitive and cost-effective signal analyzer: The Keysight N9000B CXA spectrum analyzer offers a wide frequency range from 9 kHz to 3.0, 7.5, 13.6, or 26.5 GHz with up to 25 MHz analysis bandwidth. The analyzer provides reliable support for spur searches and distortion analysis or stimulus-response measurements with the optional built-in tracking generator.

  • High-quality benchtop signal/spectrum analyzer.
  • Frequency 9 kHz to 3.0 GHz, 7.5 GHz, 13.6 GHz or 26.5 GHz.
  • DANL (Displayed Average Noise Level, at 1 GHz) -163 dBm.
  • Maximum analysis bandwidth 25 MHz.
  • Phase noise (at 1 GHz, 10 kHz offset) -110 dBc/Hz.
  • Common measurements available from the Keysight N9000B CXA: Spur search, EMI emission test, power measurements, signal analysis and more.
  • 26.9 cm touch-screen display.
  • LAN, USB, and GPIB interfaces.

Model Overview

ModelN9000B CXA-503N9000B CXA-507N9000B CXA-513N9000B CXA-526
Frequency rangeDC coupled--9 kHz...13.6 GHz9 kHz...26.5 GHz
AC coupled9 kHz...3.0 GHz9 kHz...7.5 GHz10 MHz...13.6 GHz10 MHz...26.5 GHz
Resolution bandwidth (RBW)Range (–3.01 dB bandwidth) 1 Hz...3 MHz (10% steps), 4, 5, 6, 8 MHz
Analysis bandwidth1)10 MHz standard, max. 25 MHz (option B25)
Video bandwidth (VBW)1 Hz...3 MHz (10% steps), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz)
Measurement speed (101 sweep points)Local measurement and display update rate: 11 ms (90/s) nominal;
remote measurement and LAN transfer rate: 6 ms (167/s) nominal;
marker peak search: 5 ms nominal;
center frequency tune and transfer: 22 ms nominal;
measurement/mode switching: 75 ms nominal
DANL (displayed average noise level, at 1 GHz, pre-amp. on)-163 dBm (detailed table of DANL values see datasheet)
Phase noise (noise sidebands, 20...30°C, CF = 1 GHz)1 kHz offset, –98 dBc/Hz (specification), –103 dBc/Hz (typ.)
10 kHz offset, –106 dBc/Hz (specification), –110 dBc/Hz (typ.)
100 kHz offset, –108 dBc/Hz (specification), –110 dBc/Hz (typ.)
1 MHz offset, –130 dBc/Hz (specification), –130 dBc/Hz (typ.)
10 MHz offset, –145 dBc/Hz (nominal)
TOI distortion (third order intermodulationup to +17 dBm
W-CDMA ACLR dynamic range (noise correction on)-73 dB
Amplitude accuracy±0.50 dB
Pre-amplifier (option)Option P03: 100 kHz...3.0 GHz,
option P07: 100 kHz...7.5 GHz,
option P13: 100 kHz...13.6 GHz,
option P26: 100 kHz...26.5 GHz;
gain +20 dB nominal (100 kHz...26.5 GHz)
Tracking generator (option)Option T03: 9 kHz...3 GHz,
option T06: 9 kHz...6 GHz
Display10.6"/26.9 cm, 1280x768, WXGA, multi-touch screen
InterfacesLAN/Ethernet, USB, GPIB/IEEE488
Data storageInternal: 160 GB nominal (removable solid state drive); external: Supports USB 2.0 compatible memory devices
Dimensions177 x 426 x 368; 15.4 kg

1) Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or processing in the time, frequency, or modulation domain.

Best-Value Bundles

ModelDescription
N9000B-02626.5 GHz bundle, includes:526 (9 kHz...26.5 GHz)P26 (pre-amp. 26.5 GHz)FSA (fine resolution step attenuator)PFR (portable configuration)
N9000B-0303 GHz bundle, includes:503 (9 kHz...3.0 GHz)P03 (pre-amp. 3 GHz)FSA (fine resolution step attenuator)PFR (portable configuration)
N9000B-0707.5 GHz bundle, includes:507 (9 kHz...7.5 GHz)P07 (pre-amp. 7.5 GHz)FSA (fine resolution step attenuator)PFR (portable configuration)

Optionen/Upgrades

ModelDescription
503Frequency range 9 kHz...3.0 GHz
507Frequency range 9 kHz...7.5 GHz
513Frequency range 9 kHz...13.6 GHz
526Frequency range 9 kHz...26.5 GHz
P03Pre-amplifier 3 GHz
P07Pre-amplifier 7.5 GHz
P13Pre-amplifier 13.6 GHz
P26Pre-amplifier 26.5 GHz
T03Tracking generator 3 GHz (requires hardware upgrade; not compatible with options 513 and 526)
T06Tracking generator 6 GHz (requires hardware upgrade; not compatible with options 513 and 526)
PFRPrecision frequency reference
FSAFine resolution step attenuator
B2525 MHz analysis bandwidth
PRCPortable configuration
EMCBasic pre-compliance EMC
EDPEnhanced display package
ESCExternal source control

Additional Licenced Features

The Keysight N9000B CXA signal analyzer supports more than 25 measurement applications. These applications offer various license types and terms - just send us your request.

General purposeWireless connectivityCellular communicationOthers
Analog demodulation
Vector demodulation
EMI precompliance
Noise figure
Phase noise
Pulse
WLAN (802.11a/b/g/j/p/n/af/ah)
Short-range and IoT (802.15.4 Zigbee, Z-wave; LoRa CSS)
Bluetooth
NB-IoT
LTE/LTE-Advanced FDD
LTE/LTE-Advanced TDD
LTE V2X
NB-IoT and eMTC FDD
W-CDMA/HSPA+
GSM/EDGE/Evo
Enhanced display package
Basic EMI precompliance
External source control
SCPI command compatibility

Agilent's Electronic Measurement Group is now Keysight Technologies.