Keysight N9000B CXA Signal Analyzer, 9kHz to 26.5GHz
Benefits of the N9000B CXA Spectrum Analyzer with Multi-Touch Display
- Signal/spectrum analyzer up to 26.5 GHz.
- Various options such as pre-amp., tracking generator, advanced measurements.
- Wide touch-screen display and LAN, USB, GPIB interfaces.
Keysight N9000B CXA Signal Analyzer, 9 kHz to 26.5 GHz
Design, test and educate with an intuitive and cost-effective signal analyzer: The Keysight N9000B CXA spectrum analyzer offers a wide frequency range from 9 kHz to 3.0, 7.5, 13.6, or 26.5 GHz with up to 25 MHz analysis bandwidth. The analyzer provides reliable support for spur searches and distortion analysis or stimulus-response measurements with the optional built-in tracking generator.
- High-quality benchtop signal/spectrum analyzer.
- Frequency 9 kHz to 3.0 GHz, 7.5 GHz, 13.6 GHz or 26.5 GHz.
- DANL (Displayed Average Noise Level, at 1 GHz) -163 dBm.
- Maximum analysis bandwidth 25 MHz.
- Phase noise (at 1 GHz, 10 kHz offset) -110 dBc/Hz.
- Common measurements available from the Keysight N9000B CXA: Spur search, EMI emission test, power measurements, signal analysis and more.
- 26.9 cm touch-screen display.
- LAN, USB, and GPIB interfaces.
Model Overview
Model | N9000B CXA-503 | N9000B CXA-507 | N9000B CXA-513 | N9000B CXA-526 | |
Frequency range | DC coupled | - | - | 9 kHz...13.6 GHz | 9 kHz...26.5 GHz |
AC coupled | 9 kHz...3.0 GHz | 9 kHz...7.5 GHz | 10 MHz...13.6 GHz | 10 MHz...26.5 GHz | |
Resolution bandwidth (RBW) | Range (–3.01 dB bandwidth) 1 Hz...3 MHz (10% steps), 4, 5, 6, 8 MHz | ||||
Analysis bandwidth1) | 10 MHz standard, max. 25 MHz (option B25) | ||||
Video bandwidth (VBW) | 1 Hz...3 MHz (10% steps), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz) | ||||
Measurement speed (101 sweep points) | Local measurement and display update rate: 11 ms (90/s) nominal; remote measurement and LAN transfer rate: 6 ms (167/s) nominal; marker peak search: 5 ms nominal; center frequency tune and transfer: 22 ms nominal; measurement/mode switching: 75 ms nominal | ||||
DANL (displayed average noise level, at 1 GHz, pre-amp. on) | -163 dBm (detailed table of DANL values see datasheet) | ||||
Phase noise (noise sidebands, 20...30°C, CF = 1 GHz) | 1 kHz offset, –98 dBc/Hz (specification), –103 dBc/Hz (typ.) 10 kHz offset, –106 dBc/Hz (specification), –110 dBc/Hz (typ.) 100 kHz offset, –108 dBc/Hz (specification), –110 dBc/Hz (typ.) 1 MHz offset, –130 dBc/Hz (specification), –130 dBc/Hz (typ.) 10 MHz offset, –145 dBc/Hz (nominal) | ||||
TOI distortion (third order intermodulation | up to +17 dBm | ||||
W-CDMA ACLR dynamic range (noise correction on) | -73 dB | ||||
Amplitude accuracy | ±0.50 dB | ||||
Pre-amplifier (option) | Option P03: 100 kHz...3.0 GHz, option P07: 100 kHz...7.5 GHz, option P13: 100 kHz...13.6 GHz, option P26: 100 kHz...26.5 GHz; gain +20 dB nominal (100 kHz...26.5 GHz) | ||||
Tracking generator (option) | Option T03: 9 kHz...3 GHz, option T06: 9 kHz...6 GHz | ||||
Display | 10.6"/26.9 cm, 1280x768, WXGA, multi-touch screen | ||||
Interfaces | LAN/Ethernet, USB, GPIB/IEEE488 | ||||
Data storage | Internal: 160 GB nominal (removable solid state drive); external: Supports USB 2.0 compatible memory devices | ||||
Dimensions | 177 x 426 x 368; 15.4 kg |
1) Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or processing in the time, frequency, or modulation domain.
Best-Value Bundles
Model | Description | ||||
N9000B-026 | 26.5 GHz bundle, includes: | 526 (9 kHz...26.5 GHz) | P26 (pre-amp. 26.5 GHz) | FSA (fine resolution step attenuator) | PFR (portable configuration) |
N9000B-030 | 3 GHz bundle, includes: | 503 (9 kHz...3.0 GHz) | P03 (pre-amp. 3 GHz) | FSA (fine resolution step attenuator) | PFR (portable configuration) |
N9000B-070 | 7.5 GHz bundle, includes: | 507 (9 kHz...7.5 GHz) | P07 (pre-amp. 7.5 GHz) | FSA (fine resolution step attenuator) | PFR (portable configuration) |
Optionen/Upgrades
Model | Description |
503 | Frequency range 9 kHz...3.0 GHz |
507 | Frequency range 9 kHz...7.5 GHz |
513 | Frequency range 9 kHz...13.6 GHz |
526 | Frequency range 9 kHz...26.5 GHz |
P03 | Pre-amplifier 3 GHz |
P07 | Pre-amplifier 7.5 GHz |
P13 | Pre-amplifier 13.6 GHz |
P26 | Pre-amplifier 26.5 GHz |
T03 | Tracking generator 3 GHz (requires hardware upgrade; not compatible with options 513 and 526) |
T06 | Tracking generator 6 GHz (requires hardware upgrade; not compatible with options 513 and 526) |
PFR | Precision frequency reference |
FSA | Fine resolution step attenuator |
B25 | 25 MHz analysis bandwidth |
PRC | Portable configuration |
EMC | Basic pre-compliance EMC |
EDP | Enhanced display package |
ESC | External source control |
Additional Licenced Features
The Keysight N9000B CXA signal analyzer supports more than 25 measurement applications. These applications offer various license types and terms - just send us your request.
General purpose | Wireless connectivity | Cellular communication | Others |
Analog demodulation Vector demodulation EMI precompliance Noise figure Phase noise Pulse | WLAN (802.11a/b/g/j/p/n/af/ah) Short-range and IoT (802.15.4 Zigbee, Z-wave; LoRa CSS) Bluetooth NB-IoT | LTE/LTE-Advanced FDD LTE/LTE-Advanced TDD LTE V2X NB-IoT and eMTC FDD W-CDMA/HSPA+ GSM/EDGE/Evo | Enhanced display package Basic EMI precompliance External source control SCPI command compatibility |
Agilent's Electronic Measurement Group is now Keysight Technologies.
Information on product safety:
Manufacturer:
Keysight, 1400 Fountaingrove Parkway, Santa Rosa, CA/USA
www.keysight.com
(Keysight Technologies Deutschland GmbH)