Keysight InfiniiVision MSOX3000G Series 2-/4-Channel Mixed-Signal Oscilloscope up to 1GHz
Benefits of the Keysight MSOX3000G Series Enhanced Mixed-Signal Oscilloscopes
- 8 new standard features added compared to InfiniiVision MSOX3000T series.
- I2C, SPI, UART, I2S, and USB PD trigger and decode included.
- Industry-standard, user-friendly equipment, also ideal for education.
Keysight InfiniiVision MSOX3000G Series 2-/4-Channel Mixed-Signal Oscilloscope up to 1 GHz
MSOX 3012G, 3014G, 3022G, 3024G, 3032G, 3034G, 3052G, 3054G, 3102G, 3104G
The InfiniiVision MSOX3000G new mixed-signal oscilloscope series is the ideal solution for better capturing and isolating elusive glitches and anomalies not possible on other oscilloscopes. The devices are enhanced with 8 additional standard features compared to the 3000T series, including a new waveform and measurement histograms known from the InfiniiVision 6000X series. The oscilloscope basic features are 2 or 4 analog channels plus 16 digital/logic channels (mixed-signal), bandwidths up to 1 GHz, sample rates up to 5 GS/s, a waveform capture rate of 1,000,000 Wfms/s and a standard segmented memory of 4 Mpts.
- Bandwidth: 100, 200, 350, 500 MHz, or 1 GHz (upgradeable to max. 1 GHz).
- 2 or 4 analog channels and 16 digital/logic channels for mixed signal operation.
- Sample rate: Up to 5 GS/s (half-channel), 2.5 GS/s (all channels).
- Memory: 4 Mpts (segmented).
- Display: 8.5"/21.6 cm capacitive touch-screen with gesture operation.
- Update rate: 1,000,000 Wfms/s.
- Waveform mathematics incl. FFT (windowing: Hanning, Flat Top, Rectangular, Blackman-Harris), automatic measurements, versatile trigger features.
- Integrated 5 digit frequency counter (max. frequency = max. oscilloscope frequency).
- 8 additional standard features compared to MSOX3000T series:
- Waveform and measurement histograms.
- Built-in waveform generator standard.
- I2C, SPI, UART, I2S, and USB PD trigger and decode standard.
- Mask limit testing standard.
- Measurement limit testing standard.
- Frequency response analysis (Bode plots) standard.
- Enhanced HDTV video analysis standard.
- LAN/VGA connectivity module included.
- PathWave BenchVue Software included.
Model Overview
Model | MSOX3012G | MSOX3014G | MSOX3022G | MSOX3024G | MSOX3032G | MSOX3034G | MSOX3052G | MSOX3054G | MSOX3102G | MSOX3104G |
Touch-screen | ✓ | ✓ | ✓ | ✓ | ✓ | |||||
Analog channels | 2 | 4 | 2 | 4 | 2 | 4 | 2 | 4 | 2 | 4 |
Bandwidth | 100 MHz | 200 MHz | 350 MHz | 500 MHz | 1 GHz | |||||
Sample rate | 5 GS/s half-channel, 2.5 GS/s all channels | 5 GS/s half-channel, 2.5 GS/s all channels | 5 GS/s half-channel, 2.5 GS/s all channels | 5 GS/s half-channel, 2.5 GS/s all channels | 5 GS/s half-channel, 2.5 GS/s all channels | |||||
Waveform update rate | 1,000,000 Wfms/s | 1,000,000 Wfms/s | 1,000,000 Wfms/s | 1,000,000 Wfms/s | 1,000,000 Wfms/s | |||||
Memory depth | 4 Mpts, standard segmented memory | 4 Mpts, standard segmented memory | 4 Mpts, standard segmented memory | 4 Mpts, standard segmented memory | 4 Mpts, standard segmented memory | |||||
MegaZoom | ✓ | ✓ | ✓ | ✓ | ✓ | |||||
Zone touch trigger | ✓ | ✓ | ✓ | ✓ | ✓ | |||||
Logic analysis (mixed-signal) | 16 digital channels | 16 digital channels | 16 digital channels | 16 digital channels | 16 digital channels | |||||
Trigger and decode | I2C, SPI, UART, I2S, and USB PD trigger and decode included | |||||||||
Additional functions | Waveform and measurement histograms, mask limit testing, frequency response analysis (Bode plots), enhanced HDTV video analysis | |||||||||
Signal generator | Included; standard waveforms sine (20 MHz), square/pulse (10 MHz), rampe/triangle (200 kHz), DC, noise (20 MHz), Sinc (1 MHz), exponential ries/fall (5 MHz), Cardiac (200 kHz), Gaussian pulse (5 MHz); arbitrary waveform: 1...8 kPoints, 10 bit resolution, sample-rate 100 MS/s, filter bandwidth 20 MHz; modulations: AM, FM, FSK | |||||||||
Voltmeter | Optional: ACRMS, DC, DCRMS, frequency; resolution ACV/DCV: 3 digits, frequency: 5.5 digits; measurement rate: 100 times per s | |||||||||
Counter | Source: Any analog or digital channel; resolution: 5 digits; max. frequency: Oscilloscope bandwidth | |||||||||
Display | 8.5"/21.6 cm capacitive touch gesture-enabled display | 8.5"/21.6 cm capacitive touch gesture-enabled display | 8.5"/21.6 cm capacitive touch gesture-enabled display | 8.5"/21.6 cm capacitive touch gesture-enabled display | 8.5"/21.6 cm capacitive touch gesture-enabled display | |||||
Connectivity | USB host & device, Ethernet/LAN, optional GPIB | USB host & device, Ethernet/LAN, optional GPIB | USB host & device, Ethernet/LAN, optional GPIB | USB host & device, Ethernet/LAN, optional GPIB | USB host & device, Ethernet/LAN, optional GPIB |
Included: MSOX3012, MSOX3014, MSOX3022, MSOX3024, MSOX3032, MSOX3034, MSOX3052, MSOX3054, MSOX3102, MSOX3104, power cord, 1 matching passive 10:1 probe per channel, MSO cable for 16 digital channels, standard SEC mode (secure environment), documentation CD, calibration certificate.
Note: The recommended calibration interval for these devices is 2 years. Call or send an E-Mail for more information on calibration!