Copper Mountain M Series 2-Port VNA up to 18GHz
Benefits of the Copper Mountain M Series 2-Port USB PC VNAs
- Wide frequency bandwidth from 300 kHz to 18 GHz.
- Up to 200,001 measurements sweep points with a measurement speed of 70 µs per point.
- Inbuilt programming guides for automation purpose.
Copper Mountain M Series 2-Port VNA up to 18 GHz
Models Copper Mountain M5045, M5065, M5090, M5180
The Copper Mountain M series are 2-port vector network analyzers that delivers metrology-grade performance in a more economical package (excluding a number of advanced features: Vector mixer calibration, TRL calibration, frequency offset, time domain, gating).
The VNAs include an RF measurement module/hardware and the S2 software application (depending on version optional accessory) for Windows or Linux operating system on a PC, laptop, tablet, or x86 board computer connecting to the measurement hardware via USB interface. S2 software can be installed on multiple computers, making it easy to share the use of the analyzer measurement module.
- Frequency range up to 6.5 GHz, 8.5 GHz, or 18 GHz.
- Measured parameters S11, S21 or S11, S21, S12, S22.
- Sweep types: Linear frequency, log frequency, segment, power sweep.
- Impedance 50 Ω.
Applications
RF component design and testing, on-wafer probing, field testing, insertion loss measurement, antenna matching, quality control, material measurements, and many others.
Model Overview
Model | M5065 | M5090 | M5180 |
Ports | 2 | 2 | 2 |
Frequency range | 300 kHz...6.5 GHz | 300 kHz...8.5 GHz | 300 kHz...18 GHz |
Measured parameters | S11, S21, S12, S22 | S11, S21, S12, S22 | S11, S21, S12, S22 |
Sweep types | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep | Linear frequency, log frequency, segment, power sweep |
Dynamic range (10 Hz IFBW) | 125 dB/typ. 130 dB | 125 dB/typ. 130 dB (300 kHz...6.5 GHz) 120 dB/typ. 125 dB (6.5...8.0 GHz) 115 dB/typ. 120 dB (8.0...8.5 GHz) | 115 dB (300 kHz...10 MHz) 130 dB/typ. 135 dB (10 MHz...7 GHz) 125 dB/typ. 130 dB (7...12 GHz) 122 dB/typ. 125 dB (12...16 GHz) 116 dB/typ. 120 dB (16...18 GHz) |
Measurement speed/measurement time per point | 70 µs | 70 µs | 30 µs |
Output power adjustment rate | -55...+5 dBm | -55...+5 dBm | -40...+10 dBm |
Measurement points | up to 200,001 | up to 200,001 | up to 200,001 |
Interface | USB 2.0 (USB type B) | ||
Power supply | External power adaptor | ||
Recommended accessories | Autom. cal. module ACM2506 Cal. kits N911, N912, S911T Cables and adaptors 2x C50NMNM.X, 2x C50NMNM.X + NF50, 2x C50SMNM.X Torque wrench TW-S, TW-N | Autom. cal. module ACM2509 Cal. kits N911, N912, S911T Cables and adaptors 2x C50NMNM.X, 2x C50NMNM.X + NF50, 2x C50SMNM.X Torque wrench TW-S, TW-N | Autom. cal. module ACM2520 Cal. kits N1801, S2611 Cables and adaptors 2x C50NMNM.X, 2x C50SMNM.X Torque wrench TW-S, TW-N |