ET System LAB-HP Series DC Sources 3 to 63kW

ETSYSTEM LAB-SMP Series DC Sources 3 to 63kW
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the LAB-HP(-E) Series Switch Mode DC Power Supplies up to 63 kW

  • 3 kW to 63 kW (optional 1.4 MW).
  • Output voltages up to 1,500 V (2,000 V).
  • Output currents up to 2250 A.

ET System LAB-HP Series DC Sources 3 to 63 kW

These high-performance switch mode DC voltage sources have been designed to meet the standards of industrial applications and proved highly effective wherever high performance in the smallest space is required: in laboratories and test fields, in the testing of power electronic components, circuit breakers, or solar inverters, in the development of inverters, as substitution for accumulators, and generally all tasks in the field of industrial and electronic manufacturing in which high currents are required.

  • 3 kW to 63 kW (optional 1.4 MW).
  • Output voltages up to 1,500 V (2,000 V).
  • Output currents up to 2250 A.
  • Internal temperature regulated fan.
  • TFT touch display.
  • Constant voltage, current, resistance and power operation (CV, CC, CR, CP), as well as PV-array simulation.
  • USB stick, for example for data-log function.
  • Create any type of voltage or current curve via USB stick or digital interface (sequential operation) Script operation, in conjunction with the Datalog function, enables an independent stand-alone test field to be set up.
  • Datalog function: Current operating values are saved to the USB stick at adjustable time intervals.
  • ATI 5/10 galvanically isolated analog interface: 0...5 V or 0...10 V (user selectable ) and soft interlock.
  • Adjustable filter function for the analog interface.
  • Digital interfaces GPIB/IEEE488, RS485 RS232, LAN, and USB.
  • Voltage rise time and current rise time (U and I slopes) are adjustable.
  • Vmax and Imax can be set by the user in order to limit output voltage and output current.
  • A switch-off time, that starts once the Start button has been pressed, can be set.
  • Create V/I output characteristics (e.g. for PV-Sim, shading) which can be saved on USB stick.
  • "High speed" - the rise and fall time for the DC output voltage is on average reduced by an order of magnitude compared to standard speeds.
  • OVP, OTP, OCP, and UVP (over-voltage, -temperature, -current, under-voltage) protective functions.
  • Floating output.
  • Weight and dimensions depending on model, 19" x 2/3/6/9 U x 600 or 620 mm.

The LAB-HP(-E*) series offers a variety of versions and options - please call/e-mail for an individual offer!

Model Overview

ModelkWVUinUin-Con.InterfaceOptions
LAB-HP-
LAB-HP-E-*
3 kW
4 kW
5 kW
7 kW
10 kW
15 kW
21 kW
30 kW
35 kW
45 kW
49 kW
56 kW
63 kW
15 V (3 bis 15 kW)
20 V
25 V
30 V
35 V
40 V
45 V
50 V
60 V
70 V
80 V
100 V
150 V
300 V
600 V
800 V
1000 V
1200 V
1500 V
1P/230
3P/208
3P/440
3P/480
P+N+PE
3P+PE
3P+N+PE
see options listsee options list

For example LAB-HP-21100-3P/400-3P+PE-USB

Device Features

SeriesMax. number of available digital interfacesConfigurations
LAB-HP-3RS232ATI 5/10LANMaster/slaveSoft-interlockGraphic display
LAB-HP-E-*3RS232ATI 5/10LAN--7-segment display
Mains input voltage1P/2303P/2083P/4003P/4403P/480
Grid connectionP+N+PE3P+PE3P+N+PE

* Economy version with reduced functions.

Options List

OptionDescriptionfor LAB-HPfor LAB-HP-E
DCDC input selectable between 250...750 VDCyesyes
ATEATE without manual controlyesyes
IEEE448Interface GPIB/IEEE488yesyes
RS485Interface RS485yesyes
USBInterface USByesyes
2000V2000 VDC output voltage (application must be cponsidered, please call/e-mail)yesyes
HSHighspeed, secondary rise and fall time shortened by a factor of 10yesyes
PRPolarity reversal. Only in standbyyesyes
FDFreewheeling diodeyesyes
DDSDecoupling diode serialyesyes
POPPassive overvoltage protectionyesyes
AOPActive overvoltage protectionyesyes
USB-PortUSB memeory stickyes-
IIOIncreased insulation 2000 VDC between DC output and earth at output voltages up to 300 VDCyesyes
CCConformal coatingyesyes
LOCK ACInterlock for for mains input, according to machine guidelinesyesyes
LOCK DCInterlock for for DC output, according to machine guidelinesyesyes
EMODC output emergency off: The DC output is safely short-circuited when the mains supply is switched offyesyes
SCSafety cover for mains and DC connectionsyesyes
19"19" cabinet including installation and wiring of the offered DC source(s)yesyes
CTFT touch displayyes-
CETFT display-yes
SDSD slot, only with the option GDyes-
3yExtended warranty 3 yearsyesyes
5yExtended warranty 5 yearsyesyes


Information on product safety:

Manufacturer:
ET System electronic GmbH, Hauptstraße 119-121, 68804 Altlußheim/DEU