HIOKI RM354x Series Resistance Meters

starting 1.175,72
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the RM354x Series Tester, High-Speed, High-Precision Resistance Meters

  • Series of versatile resistance meters for various application focusses.
  • Models with high speed, high-accuaracy/precision and multi-channel capabilities.
  • Interfaces options depending on model.

HIOKI RM354x Series Resistance Meters

HIOKI RM3542A, RM3543, RM3544, RM3545A Resistance Meters and Testers

The HIOKI RM354x series are resistance testers and high-speed/high-precision resistance meters. The devices offer the setting of the measurement speed to find the optimal spot between high-speed and high-accuracy.

  • Resistance meters:
    • RM3542: Resistance tester, high-speed resistance meter.
    • RM3542A: Resistance meter, high-speed resistance meter, up to 120 MΩ, resolution 0.1 µΩ
    • RM3543: Resistance tester, high-precision and high-resolution, measure 0.1 mΩ shunts with room to spare at ±0.16% accuracy & 0.01 µΩ resolution performanc.
    • RM3544: Resistance meter, basic accuracy 0.02%, 1 µΩ max. resolution, measure 0.000 mΩ (testing current 300 mA) to 3.5 MΩ.
    • RM3545: Resistance meter, super-high accuracy 0.006%, 0.01 µΩ max. resolution, measure from 0.00 µΩ (testing current 1 A) to 1200 MΩ, multi-channel capabilities.
    • RM3545A: Resistance meter, super-high accuracy 0.045%, 1 nΩ max. resolution, measure from 1 nΩ (testing current 1 A) to 1200 MΩ, multi-channel capabilities.
  • Fastest measurement time 0.9 ms (RM3542, RM3542A), 0.1 ms (RM3543), 18 ms (RM3544), or 2.2 ms/2.3 ms (RM3545(A)).
  • Finest resolution 0.1 µΩ (RM3542, RM3542A), 0.01 µΩ (RM3543, RM3545), 1 nΩ (RM3545A), or 1 µΩ (RM3544).
  • Testing source current up to 300 mADC (RM3544).
  • RM3545: 20 locations multi-point measurement and support for multiplexer unit (version -02).
  • Models with interfaces, depending on model RS232C, USB, GPIB.

Model Overview

ModelRM3542RM3542ARM3543RM3544RM3545RM3545A
Resistance rangeAt low power OFF: 100 mΩ range (max. 120.0000 mΩ, 0.1 µΩ resolution) to 100 MΩ range (max. 120.0000 MΩ, 100 Ω resolution), 10 steps
At low power ON: 1000 mΩ range (max. 1200.000 mΩ, 1 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 4 steps
At low power OFF: 100 mΩ range (max. 120.0000 mΩ, 0.1 µΩ resolution) to 100 MΩ range (max. 120.0000 MΩ, 100 Ω resolution), 16 steps
At low power ON: 1000 mΩ range (max. 1200.000 mΩ, 1 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 6 steps
(Method: Four-terminal, constant-current DC) 10 mΩ (max. 12.00000 mΩ, 0.01 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 7 steps30 mΩ (35.000 mΩ display max., 1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display max., 100 Ω resolution), 9 steps10 mΩ (12.00000 mΩ display max., 10 nΩ resolution) to 1000 MΩ range (1200.0 MΩ display max., 100 kΩ resolution), 12 steps; low power ON 1000 mΩ (1200.00 mΩ display max., 10 µΩ resolution) to 1000 Ω range (1200.00 Ω display max., 10 mΩ resolution), 4 stepsRange, testing current/measurement current:
1000 µΩ/1 A
10 mΩ/ 1 A
100 mΩ/1 A
1000 mΩ/100 mA
10 Ω/10 mA
100 Ω/10 mA
1000 Ω/ 1 mA
10 kΩ/1 mA
100 kΩ/100 µA
1000 kΩ/10 µA
10 MΩ/1 µA
100 MΩ/100 nA
1000 MΩ/1 µA or less
Measurement accuracyWith SLOW mode, at 100 mΩ range: ±0.015% rdg. ±0.002% f.s.
With SLOW mode, at 1000 Ω range: ±0.006% rdg. ±0.001% f.s. (best case)
At 10 mΩ range, with SLOW mode, average 16 times settings: ±0.060% rdg. ±0.001% f.s.±0.020% rdg. ±0.007% f.s.±0.006% rdg. ±0.001% f.s.1000-µΩ range: ±0.045% rdg. ±0.010% f.s.
10-mΩ range: ±0.045% rdg. ±0.001% f.s.
100-mΩ range: ±0.045% rdg. ±0.001% f.s.
1000-mΩ range: ±0.012% rdg. ±0.001% f.s.
1000-Ω range: ±0.006% rdg. ±0.001% f.s.
Testing current100 mADC (100 mΩ range) to 100 nADC (100 MΩ range)1 ADC (10 mΩ range) to 1 mADC (1000 Ω range)300 mADC (30 mΩ range) to 500 nADC (3 MΩ range1 ADC to 1 µA or less; low power ON: 1 mA to 5 µADCHigh mode: 1000 µΩ (1 A) to 1000 MΩ (up to 1 µA)
low mode: 100 mΩ (100 mA) to 100 Ω (1 mA)
low power mode (LP): Low power measurement with measurement current and open circuit voltage down to 20 mV
LP 1000 mΩ (1 mA) to LP1000 Ω (5 µA)
Open-terminal voltagemax. 20 VDCmax. 20 VDC (with applied voltage limit function enabled: max. 10 VDC)max. 20 VDC (voltage when not measuring is 20 mV or less, with current mode set at pulse and contact improver setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ)max. 5.5 VDC20 VDC(10 kΩ range or more), 5.5 VDC max. (1000 Ω range or less); low power ON: Max. 20 mVDCRange 1000 Ω or less: 8.0 V
range 10 kΩ or greater: 20 V
Sampling rate/
measurement speed
FAST, MEDIUM, SLOW, 3 settings
At 100 Ω /1000 Ω ranges, with low power OFF: FAST 0.9 ms, MED 3.6 ms, SLOW 17 ms (min. time);
Integration time1): 0.1...100.0 ms, or 1...5 PLC at 50 Hz, 1...6 PLC at 60 Hz
FAST, MEDIUM, SLOW;
Integration time1): At 10 mΩ range, default value: FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, setting range: 0.1...100.0 ms, or 1...5 PLC at 50 Hz, 1...6 PLC at 60 Hz
FAST 21 ms (50 MHz), 18 ms 60 ms), MED 101 ms, SLOW 401 msFAST, MEDIUM, SLOW1, SLOW2, 4 settings;
FAST 2.2 ms, MED 21 ms (50 Hz)/18 ms (60 Hz), SLOW1 102 ms, SLOW2 202 ms
FAST (2.3 ms)/MED (50 Hz: 22 ms, 60 Hz: 19 ms)/SLOW1 (102 ms)/SLOW2 (202 ms);
PR (pure resistance) 10 mΩ range: FAST (21 ms)/MED (50 Hz: 41 ms, 60 Hz: 37 ms)/SLOW1 (121 ms)/SLOW2 (221 ms)
Temperature measurement--With sensor Z2001: -10.0...99.9°C, accuracy ±0.5°C (temperature sensor Z2001 and RM3544 combined accuracy
Multiplexer---Only RM3545-02 and RM3545A-2, support unit Z3003 (install up to 2 units)
DisplayMonochrome graphic LCD 240x64 dot, white LED backlight
InterfacesRS232C, printer, external I/O, versions -01: Additional GP-IBOptional: RS232C, printer (RS232C), USBRS232C, printer (RS232C), USB, version -01: Additional GPIBLAN/Ethernet, USB, RS232C, external I/O
Dimensions (mm)260 x 88 x 300; approx. 2.9 kg260 x 88 x 300; approx. 3 kg215 x 80 x 166; 0.9 kg (RM3544), 1.0 kg (RM3544-01)215 x 80 x 307; 2.5 kg (RM3545/RM3545-01), 3.2 kg (RM3545-02)215 x 80 x 307; 2.7 kg (RM3545A-01), 3.4 kg (RM3545A-2)
VersionsRM3542: Resistance tester, high-speed resistance meter
RM3542-01: With built-in GPIB
RM3542-50: Resistance meter, high-speed resistance meter
RM3542-51: With built-in GPIB
RM3543: Resistance tester
RM3543-01: With built-in GPIB
RM3544: Resistance meter, no interfaces
RM3544-01: With built in EXT I/O, RS232C, USB interface
RM3545: Resistance meter, single-channel model
RM3545-01: With built-in GPIB
RM3545-02: Support for the multiplexer unit
RM3545A-1: Resistance meter, single-channel model
RM3545A-2: Support for the multiplexer unit

1) PLC = one power line cycle/mains wave-form period.

Included: Resistance meter RM 3542, 3542A, 3543, 3544, 3545, or 3545A, power cord, instructions maual, operation guide, models with EXT I/O: EXT I/O male connector.
Additional accessories included:
RM3544: Clip type lead L2101, spare fuse
RM3544-01: Application CD, USB cable (A-to-B type), spare fuse
RM3545(A): Clip type lead L2101, temperature sensor Z2001, application CD, USB cable (A-to-B type), spare fuse.


Information on product safety:

Manufacturer:
HIOKI E.E. Corporation, 81 Koizumi Ueda, Nagano 386-1192/JPN
www.hioki.com
(EU branch Germany)