HIOKI RM2610 Electrode Resistance Measurement System
Benefits of the RM2610 Electrode Resistance Meter System for Lithium-ion Batteries
- Measure positive and negative electrode sheets for rechargeable lithium-ion batteries.
- Measure composite resistivity (Ωcm) and interface resistance (Ωcm²).
- Complete measurement system and fixture.
HIOKI RM2610 Electrode Resistance Measurement System
The HIOKI RM2610 is an electrode resistance measurement system that consists of the components RM2611, RM2612, RM9003, RM9004, and RM9005. The system isolates and quantifies the resistance characteristics of electrode sheets, a major component of lithium-ion batteries (LIBs), as two components: The composite layer resistance and the interface resistance between the composite layer and collector. The RS22610 offers the user a possibility to visualize these two quantities by measuring the surface of the electrode sheet with a test fixture that consists of an array of test probes and then using proprietary analytical techniques to quantify them.
- Electrode resistance measurement system supports user from setup to testing.
- Separates the resistance of the positive and negative electrodes of lithium-ion batteries (LIB) into composite layer resistance and interface resistance (the contact resistance between the current collector and the composite layer) and quantifies the results for further analysis.
- Quantify composite layer resistance and interface resistance in Li-ion battery electrode sheets.
- Measure composite resistivity (Ωcm).
- Measure interface resistance between the composite layer and current collector (Ωcm²).
Model Overview
Note: The RM2611 electrode resistance meter requires regular calibration. For more information about calibration, please contact ou tech. sales team.
Model | HIOKI RM2611 |
Measurement target | Positive and negative electrode sheets for rechargeable lithium-ion batteries |
Measurement parameters | Composite resistivity (Ωcm); interface resistance (contact resistance) between the composite layer and current collector (Ωcm²) |
Computation method | Inverse problem analysis of potential distribution using the finite volume method |
Information necessary for computation | Composite layer thickness (µm, for 1 side); current collector thickness (µm); current collector volume resistivity (Ωcm) |
Measurement time | Contact check + potential measurement: approx. 30 s; calculation: approx. 35 s (on a PC with Intel core i5-7200U CPU); the measurement time may vary depending on the measurement target and the processing capacity of the PC |
Measurement current | 10 µA (min.) to 10 mA (max.) |
Number of probes | 46 |
Recommended PC specifications | CPU: 4 or more threads; RAM: 8 GB or greater (4 GB required); operating system: Windows 7 (64-bit), 8 (64 bit), 10 (64 bit) |
Temperature measurement function | Measures temperature near the test fixture |
Included: HIOKI RM 2610, temperature sensor Z2001, USB cable, USB license key, probe check board, power cord, instruction manual.
Information on product safety:
Manufacturer:
HIOKI E.E. Corporation, 81 Koizumi Ueda, Nagano 386-1192/JPN
www.hioki.com
(EU branch Germany)