HIOKI LR8431/LR8432 10-Channel Dataloggers with USB Flash Drive
Benefits of the LR8431 and LR8432 Memory Logger and Heat Flow Logger
- Dataloggers with USB flash drive and improved accuracy.
- Compact, lightweight and robust.
- Version LR8432: Heat flow logger for analyzing the causes of temperature changes.
HIOKI LR8431/LR8432 10-Channel Dataloggers with USB Flash Drive
The HIOKI LR8431-20 and LR3432-20 are high-speed data loggers for recording multiple chanels of voltage, temperature, pulse, or rotation signals. They features a bright color LCD for crystal clear waveform displays. Moreover the loggers offer complete isolation between channels and strong noise resistance.
The LR8431 logs data at 10 ms speeds across 10 channels simultaneously. The LR8432 also has 10 channel and is specialized for heat flow measurement. The heat flow logger is ideal for evaluating insulation performance and analyzing the causes of temperature change.
- 10 isolated analog and 4 pulse input channels for voltage, temperature (thermocouples), totalized pulses, and rotation count.
- 10 ms sampling and recording across all channels.
- Record measurement data on a USB flash drive for easy transfer to a computer.
- Record to reliable Compact Flash cards during long-term measurement applications for increased peace of mind.
- Replace storage media during real-time recording.
- Ultra-compact for convenient portability.
- Widescreen, bright LCD gives excellent viewability.
- HIOKI LR8431:
Improved thermocouple measurement accuracy and reference junction compensation accuracy. Noise-resistant measurement circuitry for improved readings. - HIOKI LR8432:
Use a heat flow sensor to measure the movement and volume of heat energy. Record raw waveforms and post-calculation waveforms at the same time (heat transmission coefficient processing). Two graduations can be displayed with a double gauge.
Principal applications:
Automotive market (evaluating the flow of heat into the vehicle interior from the engine compartment, assessing heat damage to vehicle parts, identifying sources of heat, etc.).
Residential construction market (evaluating the insulation performance of building materials, evaluating the performance of radiant heating systems, etc.).
Model Overview
Model | LR8431-20 | LR8432-20 |
Type | Memory logger | Heat flow logger - specialized functions for heat flow measurement: Easy scaling settings (directly enter the sensitivity of the heat flow sensor), calculations (waveform processing function for the analysis of temperature and heat flow; simple average, moving average, integration, heat transmission coefficient; integration with numerical calculations) |
Number of channels | Analog: 10 isolated analog channels using scanning input method (M3 mm dia. screw terminal block); pulse: 4 pulse input channels (requires cable 9641, all pulse inputs share common ground with the main unit) | |
Measurement parameters | Voltage: ±100 mV...±60 V (6 ranges), max. resolution 5 µV; temperature (thermocouples J, K, T, E, R, S, B, N): -200...1800°C (depending on sensor), max. resolution 0.1°C; totalized pulses: 0...1000 M pulse (1 range, no-voltage "a" contact, open collector or voltage input), max. resolution 1 pulse; rotation count: 0 to 5000/n (r/s) f.s. (1 range, no-voltage "a" contact, open collector or voltage input), resolution 1/n (r/s) | Voltage: ±10 mV...±60 V, resolution 500 nV; temperature (thermocouples J, K, T, E, R, S, B, N): -200...1800°C (depending on sensor), max. resolution 0.1°C; totalized pulses: 0...1000 M pulses (count, no-voltage "a" contact, open collector or voltage input), max. resolution 1 pulse; rotation count: 0 to 5000/n (r/s), resolution 1/n (r/s) |
Note: n = pulses per rotation (1...1,000) | ||
Recording intervals | 19 intervals between 10 ms to 1 hour (all input channels are scanned within each recording interval) | |
Selectable filters | 50 Hz, 60 Hz, or OFF (digital filtering of high frequencies on analog channels) | |
Memory capacity | Internal storage: 3.5 M-words, external storage: CF card or USB memory stick (use HIOKI CF card for correct operation) | |
External interface | USB 2.0 mini-B receptacle (control from a PC, transfers files from the installed CF card to a PC; annot transfer files from the connected USB memory stick to a PC via USB communication), data copy between CF card and USB memory stick | |
Display | 4.3"/10.7 cm WQVGA-TFT color LCD 480x272 dots | |
Functions | Save data to the CF card or USB memory stick in real time, numerical calculations, etc. | |
Power supply | AC adaptor Z1005: 100...240 VAC (50/60 Hz); battery pack 9780: Continuous use 2.5 h; 12 VDC; external supply: 10...16 V (optional cable required, on request) | |
Dimensions (mm) | 176 x 101 x 41; 550 g (without battery pack 9780) |
Included: Data logger LR8431-20 or LR8432-20, measurement guide, CD (instruction manual PDF, logger utility instruction manual PDF, data acquisition application program, logger utility), USB cable, AC adaptor Z1005.
Information on product safety:
Manufacturer:
HIOKI E.E. Corporation, 81 Koizumi Ueda, Nagano 386-1192/JPN
www.hioki.com
(EU branch Germany)