Benefits of the HIOKI LR8410-20 and LR851x Distributed Wireless Datalogging System

  • Wireless multi-channel data logger captures up to 105 data points via Bluetooth.
  • Use your windows PC or Andoid mobile device to collect data even while signals are being logged.
  • Measure voltage, temperature, pulse, clamp probes, and more.

HIOKI LR8410/LR851x Series Wireless Mini Dataloggers

HIOKI LR8410-20 Dataloggers Main Unit With Display

The HIOKI LR8410-20 and LR851x series dataloggers are a family of wireless data acquisition units. The high-speed data loggers are used to record multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8410-20 is the main unit of the wireless logging system capable of capturing up to 105 channels of data wirelessly using Bluetooth wireless technology.

HIOKI LR8512, LR8513, LR8514, LR8515, LR8520 Dataloggers with Bluetooth

  • Wireless Mini-Dataloggers.
  • Real-time monitoring with main unit/wireless logging station LR8410-20. Previous waveforms can be viewed while the device is taking measurements.
  • Select from 5 module types with I/O channels according to your application:
    • Voltage/temperature loggers LR8510 (2 channels) and LR8515 (15 channels): For applications such as various tests for electronics/automobiles/transportation, PV maintenance. Record voltage and temperature1) with a single device.
    • Universal I/O logger LR8511 (15 channels): Combines measurement of voltage, temperature1) (thermocoupes, Platinum resistance sensors), resistance and relative humidity1).
  • Pulse-Logger LR8512: The logging solution for air conditioning (flow rate), automobiles (flow rate, vehicle speed), cogeneration (flow rate).
  • Clamp logger LR8513: For use with HIOKI current sensors/clamp probes1). For PV maintenance, automobile tests, forklifts, railroads, equipment maintenance.
  • Humidity loggers LR8514, LR85201): Dataloggers fot environmental testing, construction, factories, storage, agriculture.
  • All models have 2 channels (LR8511, LR8515 15 channels), with built-in high-capacity memory for long-term recording. The LR8520 has 1 channel of input and 1 channel of alarm output.
  • Compact and space-saving, easy installation in locations where a wired solution is not possible.
  • Connect to a Android tablet, smartphone, or Windows PC for easy, wireless data collection via Bluetooth.
  • Use your PC or mobile device to collect data even while signals are being logged.
  • Check data immediately and on-site.
  • Easy logger registration: Just touch to detect, and touch to register.

Model Overview

ModelDescriptionSpecifications
LR8410-20Wireless logging station
  • Communication range 30 m (line of sight).
  • number of available registrations: 7 units (15 to 105 channels via wireless logger units).
  • Min. 100 ms interval.
  • Trend graph display.
  • Realtime recording to SD card or USB memory.
  • USB/LAN communication.
  • Display.
LR8510Wireless voltage/temperature unit
  • 15 analog channels.
  • Measure voltage (±10 mV...±100 VDC, max. 500 nV resolution) or temperature (thermocouples K, J, T, or other, -200...+2000°C depending on sensor, max. 0.01°C resolution.
  • Isolated scanning method input (2 terminals: M3 screw type).
  • Dimensions (mm) 150 x 90 x 56; 340 g.
  • Power supply AC adaptor Z1008 (100...240 VAC, 50/60 Hz), internal battery pack Z1007 (optional accessory), external power 10...28 VDC.
LR8515Wireless voltage/temperature logger
  • 2 channels, isolated; select voltage of thermocouple for each channel.
  • Measure voltage (±50 mV...±50 VDC) or temperature (thermocouples K, T, -200...999.9°C).
  • Input terminals M3 screw type terminal block (2 terminals per channel).
  • 16 recording intervals 0.1 to 30 s, 1 to 60 min. Recording mode instantaneous value.
  • Data download via Bluetooth, 500,000 data/channel.
  • Dimensions (mm) 85 x 75 x 38; 126 g (without battery).
  • Display.
LR8511Wireless univerals unit
  • 15 analog channels.
  • Measure voltage (±10 mV...±100 V, max. 500 nV resolution), temperature (thermocouples K, J, T, or other, -200...+2000°C depending on sensor, max. 0.01°C resolution), temperature (Pt100, JPt100 sensor, -200...+800°C, max. 0.01°C resolution), resistance] 0...200 Ω f.s., max. 0.5 mΩ resolution, or humidity (5.0...95.0% rel. h., optional sensor required, 0.1% resolution.
  • Isolated scanning method input (4 terminals: push-button type)
  • Dimensions (mm) 150 x 90 x 56; 320 g.
  • Power supply AC adaptor Z1008 (100...240 VAC, 50/60 Hz), internal battery pack Z1007 (optional accessory), external power 10...28 VDC.
LR8512Wireless pulse logger
  • 2 channels (common GND).
  • 16 recording intervals 0.1 to 30 s, 1 to 60 min. Recording mode instantaneous value.
  • Measurement modes: Integrating (cumulative/instant) pulse totalization, revolution, logic (records an 1/0 for each recording interval).
  • Supported input format: Non-voltage "a" contact (always-open contact point), open collector, or voltage input (0...50 VDC).
  • Data download via Bluetooth, 500,000 data/channel.
  • Dimensions (mm) 85 x 61 x 31; 95 g (without batteries).
  • Display.
LR8513Wireless clamp logger
  • 2 channels (common GND).
  • Measurement of AC load current, DC load current, AC leak current (using current sensor). Current and leak current that occur intermittently cannot be measured.
  • Software calculates the true RMS value.
  • Measurement ranges AC 500.0 mA...2000 A (with current sensor), DC 10.00...2000 A (with current sensor).
  • Measurement accuracy ±0.5% rdg. ±5 dgt. (DC, AC 50/60 Hz), add the sensor's accuracy when the current sensor is connected.
  • 14 recording intervals 0.5 to 30 s, 1 to 60 min. Recording modes instantaneous value, average value, max. value recording.
  • Data download via Bluetooth, 500,000 data/channel.
  • Dimensions (mm) 85 x 75 x 38; 130 g (without batteries).
  • Display.
LR8514Wireless humidity logger2 channels for temperature and 2 channels for humidity (2 sensors can be attached
  • Temperature measurement range -40...+80°C, 0.1°C max. resolution.
  • Humidity measurement range 0...100% rel. humidity, 0.1% resolution.
  • 14 recording intervals 0.5 to 30 s, 1 to 60 min. Recording mode instantaneous value.
  • Dimensions (mm) 85 x 61 x 31; 95 g (without batteries).
  • Display.
LR8520Wireless fungal logger1 channel for temperature and 1 channel for humidity; fungal index calculated based on temperature and relative humidity (1 sensor can be attached); output alarm signals

Included1): CD (instruction manual, logger utility, wireless logger collector), measurement guide, caution for using radio waves, AA alkaline batteries (LR6); LR 8512: Connection cable L1010; LR8511 and LR8515: AC adaptor Z1008 (with supplied power cord), bracket, M3x4 mm screws.

1) Note: Temperature sensors and current clamp probes not included, ordered separately.


Information on product safety:

Manufacturer:
HIOKI E.E. Corporation, 81 Koizumi Ueda, Nagano 386-1192/JPN
www.hioki.com