Keysight E4982A LCR Meter 1MHz to 300MHz/500MHz/1GHz/3GHz

starting 26.592,93
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the E4982A LCR Meter for High-Speed Component Tests

  • Unparalleled measurement speed and repeatability.
  • Excellent accuracy and wide impedance range, frequency range 1 MHz to max. 3 GHz.
  • LAN/Ethernet, USB, and GPIB interface.

Keysight E4982A LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz

The Keysight E4982A LCR meter provides versatile, powerful performance for tests in passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies is required. Depending on the option, the devices cover a frequency range of 1 MHz to 300 MHz, 500 MHz, 1 GHz, or 3 GHz.

  • High measurement speed: 0.9 ms, 2.1 ms, or 3.7 ms (depending on measurement time mode).
  • Low variation for repeatability.
  • Excellent accuracy and wide impedance range:
    • 11 parameters: |Z|, |Y|, L, C, R, X, G, B, D, Q, θ.
    • Measurement range from 0.14 Ω to 4.8 kΩ (within 10% accuracy)
    • 0.8% basic accuracy.
    • Sophisticated calibration/compensation method with calibration wizard function.
  • SCPI commands. GPIB, LAN/Ethernet, USB, handler interface.
  • Cable extension and small test head.
  • Multi-function comparator.
  • Contact check using DCR measurement function.
  • List measurement up to 201 points/table, table and plot format.
  • User defined function keys/parameters.
  • Undo recall/preset.
  • Context sensitive embedded help.
  • The E4982A is compatible to 4287A for drop-in replacement.

Model Overview

ModelE4982A-030E4982A-050E4982A-100E4982A-300
Frequency range1...300 MHz1...500 MHz1 MHz...1 GHz1 MHz...3 GHz
Measurement parametersImpedance parameters |Z|, |Y|, Ls, Lp, Cs, Cp, Rs, Rp, X, G, B, D, Q, θz [°], θz [rad], θy [°], θy [rad], user defined parameter (a maximum of four parameters can be displayed at one time)
Measurement rangeImpedance parameters 140 mΩ...4.8 kΩ (frequency = 1 MHz, averaging factor = 8, measurement time mode = 3, oscillator level = 1 dBm, measurement uncertainty ≤10%, calibration is performed within 23°C ±5°C, measurement is performed within ±5°C from the calibration temperature)
Measurement support functionsOPEN/SHORT/LOAD calibration, low-loss capacitor calibration, port extension compensation (fixture selection), OPEN/SHORT compensation.
DC resistance (RDC measurement range 0.1...100 Ω, resolution 1 mΩ, test signal level max. 1 mA.
Trigger function - mode: Internal, external (external trigger input connector or handler interface), bus (GPIB, USB or LAN), manual (front key).
Measurement time: 3 modes short (0.9 ms), mid (2.1 ms), long (3.7 ms).
Averaging function.
List measurement function (max. 201 measurement points for each table, 8 tables).
Test signal level monitor function
ConnectorsPorts: Type N;, measurement terminal (at test head): 3.5 mm (female; can be converted to 7 mm connector using the 3.5 mm-to-7 mm adaptor); rear panel: BNC (external reference signal input connector, internal reference signal output connector, external trigger signal input connector)
Display10.4"/26.4 cm TFT color LCD touch screen
InterfacesLAN/Ethernet, USB host and device, GPIB/IEEE488
Dimensions (mm)426 x 222 x 297; approx. 13 kg

Agilent’s Electronic Measurement Group is now Keysight Technologies.