Dx000GENB Keysight InfiniiVision Embedded Applications Software Package
Dx000GENB Keysight InfiniiVision Embedded Applications Software Package
The Keysight InfiniiVision series oscilloscope/MSO software-oriented options are available via online licensing. These software-oriented options (such as serial decoding of different buses, mask limit test, power analysis, FRA/Bode) have been bundled into application-specific packages. The packages can be registered and used according to a perpetual license. Other hardware-oriented upgrades such as signal generator, memory, bandwidths and mixed signal upgrades are available as before. The InfiniiVision 1000X series is excluded from this licencing system. The bundles GENB replace the former bundles GENA.
The embedded applications bundle includes (depending on scope model):
- I²C trigger and decode.
- SPI trigger and decode.
- UART (RS232/RS485) trigger and decode.
- I²S (audio) trigger and decode.
- USB-PD trigger and decode.
- Hardware-based decoding for responsiveness.
- Dual-bus time interleaved protocol lister display.
- Decoding of all frames captured using segmented memory.
- Real-time frame/error counter for some protocols.
Model Overview Dx000GENB
Scope model | InfiniiVision 2000A series | InfiniiVision 3000A series | InfiniiVision 3000T series | InfiniiVision 4000A series | InfiniiVision 6000A series | P9240A series | |
Bundle version | D2000GENB | D3000GENB | D3000GENB | D4000GENB | D6000GENB | P9240GENB | |
Serial trigger and decode | I²C | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
SPI | ✓ | ✓ | ✓ | ✓ | ✓ | - | |
UART (RS232/RS485) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
I²S (audio) | - | ✓ | ✓ | ✓ | ✓ | - | |
USB-PD | - | - | ✓ | ✓ | ✓ | ✓ | |
Advanced analysis | Mask test | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Frequency response analysis (Bode) | - | - | ✓ | ✓ | ✓ | ✓ | |
Enhanced HDTV video triggering and analysis | - | ✓ | ✓ | ✓ | ✓ | ✓ | |
Advanced math | standard | ✓ | standard | standard | standard | standard |
Pick the Right Probe for Your Keysight Oscilloscope
Applications | Speed and signal types | Recommended probe | Required probe bandwidth |
LIN | 625 kbps, single-ended | Passive probes (1 MΩ, single-ended) | >50 MHz |
ARINC 425 | 100 kbps, differential | ▸N2791A/▸N2818A | 200 MHz |
CAN 2.0 | 5 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
CAN FD | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
MIL Std 1553 | 1 Mbps, differential, ±25 VPP | ▸N2791A/▸N2818A | 200 MHz |
I²S (audio) | approx. 2.8 MHz, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
I²C/SMbux | <4 MHz, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
RS232/UART | <10 Mbps, single-ended | Passive probes (1 MΩ, single-ended) | >100 MHz |
RS422/485 | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
FlexRay | 10 Mbps, differential | ▸N2791A/▸N2818A | 200 MHz |
SPI | 1...100 MHz, single-ended | Passive probes (1 MΩ, single-ended) or ▸N2795A | >100 MHz passive or 1 GHz active |
MOST | 150 Mbps, differential | N2750A | 1.5 GHz |
USB 2.0 | 480 Mbps, differential | N2750A | 1.5 GHz |
USB power delivery | 300 kbps, single-ended | Passive probes (1 MΩ, single-ended) | >50 MHz |
Related Products